Honeywell RFR200 Prospecto

Descargar
Página de 1
Residential Flammable Gas Leakage 
Detector (RFR200)
Operation Instructions
Thank you for choosing Honeywell gas leakage alarm system. Please 
carefully read through the instructions before using this product, and perform 
according to the relevant procedures as provided herein to avoid any damage 
to this machine or any other incidents incurred by your inappropriate 
operation. 
The user shall assume any liability arising from or in connection with his 
or her failure to comply with the instructions in this manual and part 
installation, repair or replacement by unauthorized person. 
For the product, its color and style, please refer to the actual product as 
standard. 
Please keep this manual in a safe place for future reference. If you should 
have any doubt or dissatisfaction with our product or service, including 
product technology, quality, installation and maintenance, please contact us 
immediately so that we can deal with your suggestions in a proper way. 
Product profi le
• 
As the gas detection expert, Honeywell Analytics brings together nearly 
200 collective years of expertise in design, manufacture and technology. As 
the leader in gas detection and alarm equipment industry in the world, we 
apply high-precision detection standards to domestic gas leakage alarm 
systems. By integration of powerful catalytic fl ammable sensing technology 
and advanced electronic technology, Honeywell is dedicated to providing 
multiple protections for both our customers and their properties.
Function and indication chart
• 
 
Fixing the adapter by screw which is offered.
(Must use the machine screw to the outlet box.)
(Must use the tapping screw to the wood wall.)
While installation, ensure the wire is routed out through the reserved hole 
before installation. AC wire have to go through the adapter hole. Please 
check the direction of adapter and check the arrow and “UP” mark.
Fix the host onto the adapter for mounting with screws.
Flush mounting — in case fl ush mounting is selected, the adapter for 
mounting is not necessarily used. You need to dis-connect the AC power wire 
and remote sensor wire from main Assy and take off the adapter fi rst. 
Cut off the strip on the left edge of the host with a knife, and fi xed the 
machine body into the groove previously excavated on the wall with screws 
(detailed dimensions of the groove: width 134mm~136mm, height 92mm~ 
93mm).
      If relay is used for signal output, then remove the wire trunking and fi x it 
with screws again after connecting the signal line to the corresponding 
connecting terminal. 
Press down the panel onto the host to complete the installation.
To remove the panel, push inward the locking tab and then pull out the 
panel towards the opposite side. 
Cut off
NC
NC:Normal close
NO:Normal open
COM
COM
Fault
Alarm
•  Incorrect mounting position
Places where exhaust, steam and oil smoke from gas appliances may 
1. 
directly infl uence
Places near to the air inlet, exhaust fan, door and window where 
2. 
favorable ventilation is ensured 
Places which are fenced off by the window curtain, vertical curtain, 
3. 
cabinet door, ceiling and cross beam, etc.
Places with high temperature and moisture like cooking room and boiler 
4. 
room, etc.
Places where power supply of the alarm may possibly be switched off
5. 
Places outdoor or where the temperature is lower than -10 °C or higher 
6. 
than +55 °C
•  Precautions on using
1.  Do not switch off the power supply of the alarm, otherwise the alarm may 
not work when gas leakage occurs. 
2.  Do not touch any part of the power supply with wet hand(s) as this could 
cause risk of electric shock. 
3.  Do not remove or retrofi t the alarm.
4.  Do not use volatile matters in the vicinity of the alarm, like hair spray, 
pesticide, paint, adhesive agent and alcohol, so as to avoid false alarm an 
eliminate any infl uence on the service life of the sensitive elements. 
5.  Do not eject high-concentration gas into the access opening to avoid 
performance of the sensor. 
6.  Frequently check the power LED (green) is always on. 
7.  Press down the self-test button of the detector once every 6 months to 
check it is in normal standby state. 
8.  In case a fault happens in the alarm, please contact our company or the 
local representative offi ce immediately. 
9  Never connect the power supply to any signal output terminal. 
10. Prevent the product from falling down from a high level during installation 
and operation, otherwise the performance of the product may be impaired. 
11.  Never attempt to replace the remote probe or change the length of its 
wire by any unauthorized person. 
12. Never clean the alarm with a cleaning agent. 
13. Please keep the alarm away from silicon-contained material.  
•  Our company will not assume any responsibility for 
product damage or loss of function caused by the 
following reasons: 
1.  Consumer’s disassembly or intentional damage
2.  Force majored like fi re, earthquake, lightening, abnormal voltage, etc.
3.  Wrong installation position or failure to switch on power supply of the 
detector
4.  Expiration of the lifetime
5.  Falling down, impact and other faults and damages incurred by the 
consumer
6.  Other contamination, damages, faults or damages not caused by the 
manufacturer 
Honeywell Trading (Shanghai) Ltd
430 Li Bing Road
Zhangjiang Hi-Tech Park
Shanghai, China
1.   Power LED (green): indicates the power system is in normal operation
2.   Alarm LED (red): indicates the concentration of combustible gas 
leakage reaches the set value 
3.   Fault LED (yellow): indicates the alarm is in fault condition
* Alarm relay shall be teseted often 5 seconds of button when normal conduction. 
•  Procedures for control panel installation
Find an appropriate installation point on the wall.
•  Procedures for remote sensor installation
Fix the sensor onto the ceiling with screws.
Service life and warranty period
• 
1.   The optimal service life is fi ve years (since the purchase, please keep 
your invoice).
2.   The warranty period for free is one year (since the purchase).
3.  User must read through this instruction manual carefully and operate 
correctly, and Honeywell will repair or replace for free in case the machine 
does not work due to any quality issue at the manufacturer’s side.
•  Operation Standard: GB15322.2-2003
•  Detection Gas :LNG
• Installation 
instruction
The detector should be installed in the room with gas consumed 
equipment, and the alarm shall have a horizontal distance of 3m or less from 
the gas consumed equipment. In case natural gas is used, the detector may 
be installed at the height with a 30m distance or less from the ceiling. 
Front cover assy
Strain relief
Main assy
Adapter
Remote sensor
cable
Remote sensor
connector
H_RFI Manual_09_V1_AP
When detects gas, it will give the 
alarm signal continuously. The red 
LED and sounder will annunciate 
When gas level is less then alarm 
point, return to normal operation.
Operation
Description
Timing/Interval
When no gas is present, the green 
LED 
Always G LED on if 
power is normal
Same as default condition
3 long chirps/min
1 long chirps/min
2 long chirps/min
Continues beep
De
De
De
De
En
En
En
De
En
De
De
De
De
De
En
En
En
De
En
En
8 times beep with red 
LED fl ash 4 times and 
then yellow LED fl ash 
4 times
LED
Relay
G
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y Y Y
Y
Y
Y
Y
N
N
N
N
N
N
N
N
N
Y
N N
N
N
N
N
Y
Y
Y
Y
Y
Y
R Y Al Ft
B
u
z
z
On demand test result by press the 
button. Red LED and Yellow LED will 
be blink in order. After then return to 
normal mode
If required, the audible alarm can be 
silenced for 5 minutes by pushing 
the button marked “Test”. The red 
alarm will continue to fl ash for 5 
minutes
If gas is still present after 5 minutes 
hush period, the audible alarm will 
sound
Cell health trouble/No cell
Power trouble
EEPROM CRC fail/ Program 
code fail
End of life time(5 years)
Normal 
Operation
Alarm
Successful
Test*
Hush
Function
Red LED fl ash 4 times 
each time
8 times beep with red 
LED fl ash 8 times
Same as alarm condition
On demand test result by press the 
button. After then  return to normal 
mode
Unsuc-
cessful Test
Trouble
Condition
Power LED (green)
Alarm LES (red)
Fault (yellow)
Detecting natural gas
3m or less
30cm or less
1.2m-1.6m
Remote sensor
Screw
Remote sensor
Check that each part or component is in good condition before 
installation, and get prepared the screws and other attachments we’ve 
provided in the toolkit. 
•   Part description
      
Control panel