INTRODUCTION
General Information
These fi replaces are conventional heat circulat-
ing appliances with standard grates, outside 
combustion air kit and standard decorative 
glass doors.  The BCD36MH model is fi tted 
with a blower and is available as an option for 
model BC36MH.
The grate included properly positions the fi re and 
limits the amount of fuel. IF A REPLACEMENT 
GRATE IS NEEDED REPLACE THE GRATE WITH 
MODEL 87L20 ONLY.
Note: Illustrations shown refl ect “typical” 
installations with nominal dimensions and 
are for design and framing reference only. 
Actual installations may vary due to individual 
design preferences. However, always maintain 
minimum clearances to combustible materials 
and do not violate any specifi c installation 
requirements.
These fi replaces have been tested and listed 
by Warnock Hersey (Report No. J99025865A) 
to U.L. standard 127. These units are intended 
for installation in manufactured homes.  These 
units may also be installed in buildings of con-
ventional construction including commercial, 
providing all instructions provided herein are 
strictly adhered to.
These fi replace systems are designed for in-
stallation in accordance with the National Fire 
Protection Standard for chimneys, fi replaces 
and solid fuel burning appliances; NFPA 211-
latest edition and in accordance with codes 
such as the BOCA Basic/National Codes, the 
Standard Mechanical Code and the Uniform 
Building Codes.
The minimum installed height of the completed 
fi replace system is 10' 6".  The maximum height 
is 40' 0".  See the Chimney Height section on 
Page 3 for more information.
The fi replace and chimney system must be 
enclosed when installed in or passing through 
a living area where combustibles or people may 
come in contact with it. This is important to pre-
vent possible personal injury or fi re hazard.
For questions, please call your distributor or 
the manufacturer. Special restrictions apply to 
the front and facing of the fi replace and nearby 
walls (See Pages 16 and 17).
CHIMNEY SYSTEM
These fi replaces are designed and code listed for 
use with Security Chimneys FTF8 chimney sys-
tem only. Always use Security Chimneys FTF8 
chimney components with these fi replaces. Do 
not modify or alter these components as this 
may cause a potential serious hazard and void 
the Warranty.
*Construction Materials:
 
• Framing Materials • Paneling
 
• Particle Board 
• Flooring
 
• Dry Wall 
• Plywood 
 
• Noncombustible Insulating Materials
 • 
Etc.
Chimney Height
The total height of your completed fi replace 
system from the surface the fi replace rests on to 
the chimney top must not exceed 40' and must 
also meet minimum height requirements. Refer 
to the minimum system height chart.
TYPICAL 
INSTALLATION
       WARNING 
Failure to use manufacture 
provided parts, variations in 
techniques and construction 
materials or practices other than 
those described in this manual 
may create a fi re hazard and void 
the limited warranty.
       WARNING 
Do not pack or fi ll required air 
spaces with insulation or other 
material. No material is allowed 
in these areas.  Secure the 
airspace around the chimney 
with the fi restop/thimble before 
completing the installation. 
 
Maintain 1" clearance between 
chimney and thimble.
When complete these fi replace systems con-
sists of four basic “sub-systems”:
1. The Fireplace
2.  The Chimney and Termination
3. Glass Doors
4. Combustion Air Kit
CLEARANCES AND HEIGHT
REQUIREMENTS
The fi replace may be placed on or near normal 
construction materials*. The combustion air 
kit, fi restop spacer and roof fl ashing (not chase 
fl ashings) may be placed directly on or against 
normal construction materials.* The chimney 
and fi replace outer wrapper require a minimum 
1" air space to insulation and building materi-
als. A combustible mantel may be installed 12" 
above the opening of the fi replace as per NFPA 
211-latest edition.
       WARNING 
If insulation is used, the fi replace 
must not be placed directly 
against it. Insulation or vapor 
barriers, if used, must fi rst be 
covered with gypsum board, 
plywood, particle board or other 
material to assure insulation and 
vapor barriers remain in place.
Chimney and 
Termination
Outside Combustion Air Kit
Firestop
Thimble
Minimum System Height
Security's FTF8 Pipe
Vertical Installation
10' 6"
One Offsets
12' 0"
Two Offsets
25' 0"
Table 1