24
CDVX Series Direct Vent Gas Fireplace
20012253
1
2
3
4
Example: 
 
Elbow 1  =  90°
 
Elbow 2  =  45° 
 
Elbow 3  =  45°
 
Elbow 4  =  90°
  Total angular variation  =  270°
1 + 2 + 3 + 4 = 270°
FP1239
Fig. 48  Maximum number of elbow degrees.
STEP 2
Place fireplace into position. (Fig. 49) Measure the verti-
cal height (X) required from the base of the flue collars 
to the center of the wall opening.
STEP 3
Attach appropriate venting component(s) to the fire-
place with three (3) screws. (Fig. 50) Follow with the 
installation of the inner and outer elbow. Again secure 
joints with three (3) sheet metal screws. 
X
FP1240
Fig. 49  Vertical height requirement.
STEP 4
Measure the horizontal length requirement including 
a 2” (51 mm) overlap, ie from the elbow to the outside 
wall face plus 2” (51 mm) (or the distance required if 
installing a second 90° elbow). (Fig. 50)
Always install horizontal venting on a level 
plane.
STEP 5
Use appropriate length of pipe sections - telescopic or 
fixed - and install the horizontal vent sections. The sec-
tions which go through the wall are packaged with the 
starter kit, and can be cut to suit if necessary. (Fig. 48)
Sealing the gaps between the vent pipe 
and firestop with high temperature sealant 
will restrict cold air being drawn in around 
fireplace.
STEP 6
Guide the vent terminations 4” and 7” collars into their 
respective vent pipes. Double check that the vent pipes 
overlap the collars by 2” (51 mm). Secure the termina-
tion to the wall with screws provided and caulk around 
the wall plate to weatherproof. (Fig. 52) As an alterna-
tive to screwing the termination directly to the wall you 
may also use expanding plugs or an approved exterior 
construction adhesive. You may also attach the termi-
nation with screws through the inner body into the 4” 
(102 mm) vent pipe however for this method you must 
extend the 4” (102 mm) pipe approximately 6” (152 mm) 
beyond the outer face of the wall.
Support horizontal pipes every 3’ (914 mm) with metal 
pipe straps. Make sure the horizontal vent pipe is in-
stalled on a level horizontal plane.
X
FP1241
Fig. 50  Horizontal length requirement.