Monessen Hearth 36CDVXTRN Manual De Usuario

Descargar
Página de 44
8
CDVX Series Direct Vent Gas Fireplace
20012253
A hearth is not mandatory but is recommended for  
aesthetic purposes.  We recommend a noncombustible 
hearth which projects out 12” (305 mm) or more from 
the front of the fireplace.
Cold climate installation recommendation:  
When installing this unit against a 
non-insulated exterior wall or chase, 
it is mandatory that the outer walls 
be insulated to conform to applicable 
insulation codes.  
Hearth
Framing and Finishing 
Check fireplace to make sure it is levelled 
and properly positioned.
To mount the appliance:
1.  Choose the location.
2.  This unit comes with four (4) flanges pre-mounted 
on both sides of the fireplace to allow two different 
drywall thicknesses to be used. Flange “A” is for 1/2” 
drywall while flange “B” is for 5/8” drywall.
3.  Bend the desired flanges out 90° on both sides of 
the fireplace. Slide the fireplace into the framed 
opening until the flanges contact the front surfaces 
of the framing. Level the unit and secure it firmly in  
place.
4.  The standoffs are adjustable for different drywall 
thicknesses. The unit is shipped from the factory at 
1/2” (13 mm). Loosen the four (4) screws securing 
each standoff to the top of the fireplace. Slide the 
standoff back. Tighten the screws. This yields a 5/8” 
(16 mm) thick drywall space. Removing the standoff 
and having the tabs on the standoff face the rear of 
the unit yields a 3/4” (19 mm) drywall space. (Fig. 5)
NOTE: Drywall must stop at standoffs and not touch 
top of unit.
Hood Installation
CAUTION: Hood MUST be permanently installed.
1.  Remove top louvre. Carefully remove hood from 
inside top louvre opening. 
2.  Remove three (3) sheet metal screws in bottom 
flange of fireplace surround top.
3.  Install the hood by aligning the three holes in bottom 
flange of fireplace surround top. (Fig. 6)
4.  Secure hood to bottom flange of fireplace surround 
top using three screws removed in Step 2. (Fig. 6)
5.  Carefully remove protectors under the relief plates 
on top of the firebox.
6.  Replace top louvre.
A
B
FP1603
flange location
12/05
Fig. 5  Nailing flanges and standoffs.
 
Flange 
Drywall
  Position 
Depth
 
1/2” / 13 mm
 
5/8” / 16 mm
Flange Location for Desired 
Drywall Depth at Stud Wall
FP1603a
standoff location
3/06
Screws
Tabs
Standoff Location for Desired Finish Wall Depth at 
Header
FP1603a
FP1603
&0
INSTALL
Hood
Sheet 
Metal 
Screws
FP1609
Fig. 6  Secure hood to fireplace with sheet metal screws.
Noncombustible materials such as brick or tile may be 
extended over the edges of the face of the fireplace. 
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the 
brick or tile will have to be installed flush with the edges 
of the fireplace.
Final Finishing