INST
ALLA
TION
RIGID PIPE VENTING SYSTEMS
BASIC HORIZONTAL & VERTICAL TERMINATIONS
Rigid Pipe Vent Systems offer a complete 
line of component parts for installation of both 
horizontal and vertical installations. Many items 
are offered in decorative black, as well as gal-
vanized fi nish. 
The minimum components required for a basic 
horizontal termination are:
 1 AstroCap 
XL
 1 90
o
 Elbow 
 1 Rigid 
Pipe 
Adaptor
 1 Wall 
Thimble
  1  Length of pipe to suit wall thickness 
The minimum components required for a basic 
vertical termination are:
 1 Vertical 
Termination 
Cap
 1 Rigid 
Pipe 
Adaptor
  1  Lengths of pipe to adequately
   penetrate 
roof
 1 Ceiling 
Firestop
 1 Flashing
 1 Storm 
Collar
Wall thickness  is measured from the back 
standoffs to the inside mounting surface of 
termination cap. For siding other than vinyl 
furring strips may be used, instead of the vinyl 
siding standoff, to create a level surface to 
mount the vent terminal. The Terminal must 
not be recessed into siding. Measure the wall 
thickness including furring strips.
If a Vinyl Siding Standoff is required (it must 
be used with vinyl siding), measure to outside 
surface of wall without siding and add 2 
inches.
Alternate 
Horizontal Termination 
Caps
When using Rigid Vent other than
Simpson Dura-Vent, 3 screws must be 
used to secure rigid pipe to adaptor.
The FPI AstroCap XL
TM 
is certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent
®
 Direct Vent Pro and Selkirk Direct-Temp. 
AstroCap XL
TM
 is a proprietary trademark of FPI Fireplace Products International Ltd. Dura-Vent® and Direct Vent GS are registered and/or proprietary 
trademarks of Simpson Dura-Vent Co. Inc.
      
This product has been evaluated by Intertek 
for using a Rigid Pipe Adaptor in conjunction 
with Simpson DV Pro, Metal-Fab Sure-Seal 
and Selkirk Direct-Temp systems. Use of these 
systems with the Rigid Pipe adaptor is deemed 
acceptable and does not affect the Intertek WHI 
listing of components.
WARNING:
Do not combine venting components from 
different venting systems.
Expection: However, use of the the AstroCap 
XL
TM
 is acceptable with all systems.
INSTALLATION
Part # 5DT-ST14 (14")
Part # 5DT-ST36 (36")