Regency L900-1 Manual De Usuario

Descargar
Página de 48
Regency
®
 L900-1 Direct Vent Gas Fireplace
37
INST
ALLA
TION
INSTALLATION
Optional Andiron installation for the L900-1:
1)
 Remove the mesh and the glass door (see Page 30 in the manual).
2)
  Remove Log G from the log set - see below.
Optional Andiron installation for the L676-1:
1)
 Remove the mesh and the glass door (see Page 30 in the manual).
2)
  Remove Log B from the log set - see below.
3)
  Slide bracket on the back of andiron over the 1st grate post.
4)
  Replace Log G.
3)
  Slide the bracket on the back of the andiron over the 1st grate 
post.
4) 
 Replace Log B (see below).
5)
 For the right side, slide the andiron bracket over the 
    4th grate post.
6)
 Reinstall glass door and mesh.
5)
 For the right side, slide the andiron bracket over the 
    4th grate post.
6)
 Reinstall glass door and mesh.
Log G
1st Grate Post
4th Grate Post
Log B
Final Installation L900-1
Final Installation L676-1
4th Grate Post
Right Side
1st Grate Post
Andiron  Bracket
Andiron  Bracket
Adjustments
Note: 
 Andiron bracket 
can be adjusted by 
bending.  
    Also the screw can 
b e   l o o s e n e d   s o 
the bracket can be 
adjusted higher or 
lower.
Log B