INSTALLATION
VENTING 
INTRODUCTION
The  P90  uses  the  "balanced  fl ue"  technology 
Co-axial system. The inner liner vents products 
of combustion to the outside while the outer liner 
draws outside combustion air into the combustion 
chamber thereby eliminating the need to use 
heated room air for combustion and losing warm 
room air up the chimney.
Note:  These flue pipes must not be 
connected to any other appliance.
The gas appliance and vent system must be 
vented directly to the outside of the building, 
and never be attached to a chimney serving a 
separate solid fuel or gas burning appliance. 
Each direct vent gas appliance must use it's own 
separate vent system. Common vent systems 
are prohibited.
Side Nailing Strips
The side nailing strips come attached to the unit. 
There are 2 plates, one on the top and bottom 
that can be folded out as required.
Plates can be 
folded out.
1)  Ensure top clip screws are at top of oblong 
holes before installation.
Back View of
Cover Plate
Pin Holes
Top Clip
Pins
2)  Position bottom of cover plate over pins 
located at the bottom of the  fi rebox. 
Oblong Screw 
Holes
3)  Bring cover plate towards the unit and hook 
top clip over and behind the glass frame.
 
The top clip may need to be adjusted. Loosen 
the 2 screws that secure the top clip to let 
the cover plate settle over and behind the 
glass frame. Once settled tighten screws.
TO REMOVE:
1)  Remove 2 screws that secure top clip. Ensure 
to hold cover plate as it will fall forward.
2)  Pull out top clip that is still hooked onto 
glass.
OPTIONAL COVER 
PLATE TEMPLATE
UNIT ASSEMBLY 
PRIOR TO 
INSTALLATION
The 2 Top Standoffs must be correctly 
positioned and attached to the top before unit 
is slipped into position. 
Top Standoff Assembly
The top standoffs are shipped in a fl at position 
and must be folded into shape and attached.
1)  Remove the standoffs from the fi replace 
top.
2)  Take each standoff and bend into the 
correct shape. Bend up at the bend lines 
until the screw holes in the standoff and the 
pre-punched screw holes on the fi replace  
top line up. 
3)  Attach the standoff securely to the top 
with 2 screws per standoff (on opposite 
corners).