CarAlarms.com P90-NG1 Manual De Usuario

Descargar
Página de 48
Excalibur
®
 P90 Zero Clearance Direct Vent Gas Fireplace
40
12) Undo the pilot tube from the valve with a 
 7/16" 
wrench.
13) Undo the quick drop out thermocouple nut 
on the valve with a 9mm (metric) wrench.
14) Remove the Piezo igniter wire and push 
button assembly.  
15) Undo the "gas out" fl are nut with a 13/16" 
wrench.
16) Undo the "gas out" fl are fi tting with an 
 11/16" 
wrench.
17) Remove the 4 Phillips head screws from 
the sides of the valve bracket and remove 
valve.
Hint: 
If you are using black pipe, ensure 
that there is a union by the valve, 
otherwise removal will be almost 
impossible.
INSTALLING VALVE
1)  Attach the valve to the valve bracket with 
the 4 (m5x8 metric) screws provided.
2)  Reconnect the "gas out" fl are fi tting with an 
11/16" wrench.
3)  Reconnect the "gas out" fl are nut with a 
13/16" wrench.
4)  Install piezo ignitor push button assembly 
and reconnect wire.
5)  Reconnect the quick drop out thermocouple 
nut with a 9mm wrench.
6)  Reconnect the pilot tube nut with a 7/16" 
wrench.
7)  Scrape off the old gasket from the fl oor of the 
fi rebox and from the valve tray assembly.
8)  Install a new gasket and reinstall the valve 
tray assembly.
Note: Failure to install a new gasket may 
severely affect the appliance performance.
9)  Reinstall the 10 hold down screws.
10) Hook up the 2 TP and 2 TH wires to the 
appropriate connections on the valve.
11)  Reinstall the bottom brick panel,  then screw 
the 2 screws & sleeves through the brick 
panel to the fi rebox base (reversing step 8) 
leaving them about 1/4" (6mm) above the 
brick panel.  Reinstall the rear log stand.
12) Install Burner/grate assembly
13) Hook up the gas line and check for gas 
leaks with a soap and water solution or a 
gas leak detector. (Do not use open fl ame 
for leak testing.)
14) Fire up the unit temporarily
15) Check the manifold pressure.
16) Reinstall the logs and brick panels as 
needed.
17) Reinstall the glass door and the facade.
18) Fire up the unit again and check for proper 
fl ame appearance and glow on logs.
REMOVING VALVE
1)  Shut the power off.
2)  Open the bottom louver door. Loosen the 2 
screws holding the Burner ON/OFF switch 
and bracket to the bottom louver and lift the 
assembly out.
3) Remove 
the 
facade 
if 
installed. 
4)  Remove the glass door (Refer to the "Glass 
Door Installation" section).
5)  Remove the logs.
6)  Remove the burner/grate assembly by 
removing the two Phillips head screws and 
then slide the burner assembly to the left 
and lift out.
Diagram 1: Remove the left and right  screws 
and then slide the burner/grate assembly to 
the left and lift out.
7)  Remove the rear log stand by removing the 
2 screws.
Rear Log Stand
screws
9)  Disconnect the inlet gas line. See dia. 2.
10) Disconnect the 2 TP wires and the 2 TH 
wires from the valve.
11) Remove the 12 Phillips head screws securing 
the valve tray assembly in place and then 
lift the entire assembly out.
screws
Valve Tray Assembly
8)  Remove the 2 screws & sleeves on the 
bottom brick panel and lift out the bottom 
brick panel. The brick panel is very  fragile 
- handle with care.
screws
MAINTENANCE