Vermont Casting 2478 Manual De Usuario

Descargar
Página de 32
13
Dutchwest Non-Catalytic Convection Heater
30002278
1.   Shielding for a top exit stove must include a flue collar shield to protect the area behind the flue collar.
2.  Chimney connector heat shields must extend exactly 24” (610 mm) above the flue collar of the stove.
3.  Dimension is to the top plate of the stove, not the back wall of the stove.
Stove and Chimney Connector Clearance Charts
  
Stove Clearance 
Side 
Rear
3
 
 Corner 
Side 
Rear
3
 
Corner
  No heat shields 
(A)  20” 
(B)  25” 
(C)  15¹⁄₂” 
(D)  7” 
(E)  19” 
(F)  10¹⁄₂”   
   
(508 mm) 
(635 mm) 
(394 mm) 
(178 mm) 
(483 mm) 
(267 mm)     
  Rear exit, 
(G)  16” 
(H)  12” 
N/A 
N/A 
N/A 
N/A 
 
  flue collar heat shields 
(406 mm) 
(305 mm)
  Top exit
1,2
, flue collar 
(K) 14” 
(L)  15” 
(M)  7¹⁄₂” 
(N)  7” 
(O)  11” 
(P)  7”
 
 
  Single-wall connector 
(356 mm) 
(381 mm) 
(191 mm) 
(178 mm) 
(279 mm) 
(178 mm)               
  w/connector heat shield 
Right Side 
 
 
Right Side 
 
 
 
  and right side heat shield 
Only 
 
 
Only
  Top exit
, flue collar 
(K)  17” 
(L)  15” 
(M)  7¹⁄₂” 
(N)  8” 
(O) 14¹⁄₂” 
(P)  7” 
 
  heat shield, 
(432 mm) 
(381 mm) 
(191 mm) 
(178 mm) 
(368 mm) 
(178 mm)   
  Double wall connector
  Chimney Connector Clearance:
  Single-wall connector 
 
20”   
 
 
14”   
 
 
  No connector heat shield 
 
(508 mm) 
 
 
(356 mm)
  Single-wall
 connector 
 
10” 
 
 
6” 
 
 
  w/connector heat shield 
 
(254 mm) 
 
 
(152 mm) 
 
 
  & flue collar heat shield 
  Double-wall connector 
 
10” 
 
 
9¹⁄₂” 
 
 
  & flue collar heat shield 
 
(254 mm) 
 
 
(241 mm)
  Front Clearance to Combustibles:  
(All Installations) 
 
 
48” (1219 mm) 
 
Model 2478 Medium Convection Heater
  
UNPROTECTED SURFACES 
 PROTECTED SURFACES
 
 
Corner 
 
Corner
 
Parallel Installations 
Installations  Parallel Installations 
Installations
Important:
When choosing an installation utilizing the side loading door located on the left side of the stove, follow the 
minimum dimensions given in the Stove and Chimney Connector Chart on Page 13 and the Minimum Dimen-
sions for Noncombustible Floor Protectors given on Page 9, Figure 12.
For operation of the side loading door, the minimum clearances on the left side of the stove for usable opera-
tion is 13” (330 mm) in a corner installation and 18” (457 mm) in a parallel installation.