1.  Switch off the main power switch and disconnect the power cord from the power source. 
 
2.  Open the PSU box [A]. 
To set the connector 
1.  Connect the white connector [B] to CN602 on the AC drive board [C]. 
 
NOTE
 
  Connect the large connector clamped beneath the board. 
  This step is not required if the LCIT anti-condensation heater will be connected. 
To supply power 24 hours a day 
Doing the connection in the previous procedure assures that power is supplied to the machine 
for the heaters even after the main machine is switched off 
with the main power switch (for 
example, in auto off mode)
. However, with only this connection, the heaters do not operate 
while the main machine is operating. 
Another connection can be done so the heaters in the paper tray unit will 
stay on continuously.  
The ‘24 hours a day’ connection applies only to the tray heaters, not the transfer and 
scanner units.