Harman Stove Company 1-90-797000 Manual De Usuario

Descargar
Página de 40
26
 Dry Seasoned Wood Only!                                                              3-90-798                                                                 Save These Instructions
Oakleaf Woodburning stove
E.  Before your first fire
•  Be sure the appliance is installed properly and that 
all safety requirements have been met. Pay par-
ticular attention to the clearances to combustibles, 
floor protection and the venting instructions.
•  Test your smoke detector(s) and CO detector(s) to 
the specifications of the manufacturer.
•  Double check that the ash pan and internal firebox 
are empty.
•  Be sure to read this entire manual.
f.  Building and Maintaining a fire
Minimum 
Primary Air
Maximum 
Primary Air
For  low  burn,  slide  the  air  control  to  the  left.  For 
medium burns, use notches 1 to 2. Maximum heat is 
attained with the air control all the way to the right. Do 
not burn the stove continuously at the maximum setting. 
If maximum heat is required day after day, the stove is 
too small for the area you are trying to heat.
If your wood is not seasoned long enough or is high 
in moisture content, you may need to adjust the primary 
air  slightly  higher  to  sustain  a  low  burn  rate  with  the 
cleanest possible exhaust.
Begin  with  the  bypass  damper  open,  and  the  air 
control lever at the maximum setting, all the way to the 
right. Be sure the ash pan door is closed and latched.  
Start with a bed of crumpled paper and kindling sized 
about finger width; place several 1" - 2" (25mm - 50mm) 
split pieces of dry wood on top of the kindling, followed by 
a few 2" - 3" (50 mm - 80 mm) split pieces. Lay the wood 
in a crossed pattern to allow maximum air flow. Ignite 
the paper and close the loading door(s). Allow this start-
up fire to burn for a few minutes, keeping the bypass 
damper open. Add about five more pieces of wood in the 
2 to 3 inch (50 - 80mm) size range, making sure that the 
fuel bed is all the way across the firebox and staggered 
to allow airflow. Close the door and allow this loading 
to burn a few minutes. 
Add increasingly larger pieces of wood to the fire until 
you have a thick bed of hot embers, approximately 2 to 
3 inches deep at the back of the grate and at least an 
inch deep at the front. You must have this charcoal bed 
established before you close the bypass damper.      
Two important controls - the damper bypass handle 
and  the  air  control  lever  regulate  the  operation  and 
output of the stove.
To open the top or front loading door, you must open 
the damper bypass, or smoke will come in the room. In 
this mode of operation the combustion gases go directly 
from the main combustion chamber to the flue collar and 
exit into the chimney.
 
NOTE:    The  bypass  damper  must  be  open  for 
smokeless loading.  Open the bypass damper by turn-
ing the handle clockwise while facing handle.
Bypass Damper 
Open
Bypass Damper 
Closed
d.  user Controls
The air control lever is located directly below the load 
door. Sliding this lever allows you to vary the amount 
of air to the fire, creating a range of heat outputs. The 
lowest heat output setting is to the left, and the highest 
is to the right. The notches are provided as a reference 
for your comfortable heat settings. Do not, under any 
circumstances, alter the configuration or operation of 
the air control lever.
dO NOT OvERLOAd THE APPLIANCE. dOORs MusT 
BE CLOsEd WHEN IN OPERATION.