Installation
309524L
9
Cart Mounting 
(F
IG
. 5)
1.
Place clamps (AA) around the cart vertical post 
(DD) and secure to the heater mounting bars (ZZ) 
with M8 x 1.25 x 30 mm bolts (6) and lockwasher 
(5).
2.
Observe temperature ratings for the power cable to 
the terminal junction. Cable H07RN does not meet 
the required 221°F (105°C). An intermediate Type 
“e” junction may be required. Also see F
Fluid Connections & 
Accessories 
1.
Install a fluid shutoff valve (T) in the heater’s 1/2-14 
npt(m) fluid inlet; do not overtighten. Connect the 
fluid line to the valve.
2.
Provide a means for adequately handling fluid 
expansion caused by heat. Options include:
Use flexible hoses between heater and gun.
Install a properly sized accumulator down-
stream from the heater.
Install a pressure relief valve (X) pre-set to 
relieve pressure when it exceeds the system 
maximum working pressure.
3.
Install a fluid filter (L), drain valve (M), and fluid pres-
sure regulator (N) near the heater’s 1/2-14 npt(f) 
fluid outlet. Then connect the fluid line.
You need to have 2 each of cart mounting bar 
183485 and clamp 183484. See Accessories
page 26, to order. 
F
IG
05543-524
DD
6
5
AA
ZZ
WARNING
To avoid rupturing a component, which can cause seri-
ous injury, including amputation; read warnings, page 
4, and follow the instructions below.
Never install a shutoff device between the 
heater and gun as this will trap the heated fluid 
and not allow for expansion. If a fluid regulator 
is installed between the heater and gun, never 
use it as a shutoff device.
F
IG
05545-524
T
X
N
L
M