tecHnical speciFicatiOns
MH 1000id
Hs 1000id
MH 2000id
Hs 2000id
MH 3000id
Hs 3000id
Hs 4000id
Heat input
[kBTU/h]
110
205
300
400
Air flow
[cfm]
880
1,530
2,500
2,760
Fuel Type
Diesel/Kerosene/#1-2 Fuel Oil
Heat output
[kBTU/h]
91.9
174.9
254.4
335.6
Fuel consumption
[gal/h]
0.80
1.48
2.28
2.82
[lb/h]
5.53
10.35
15.07
20.07
Power supply
Phase
1
1
1
1
Voltage
[V]
120
120
120
120
Frequency
[Hz]
60
60
60
60
electric consumption
[W]
520
785
1.240
1.440
[A]
5.76
8.30
11.40
13.20
Nozzle
[USgal/h]
0.60-80° S
1.00-45° W
1.20-45° W
1.50-45° W
Pump pressure
[psi]
167
P1: 137
P1: 160
P1: 203
P2: 239
P2: 350
P2: 348
Max static pressure
[in WC]
0.5
0.5
0.5
0.5
Recommended max. temp. in the air 
duct
[°F]
250
250
250
250
Adjustment of combustion air flap
[in]
a=0.32
-
-
-
-
A=1.02
A=1.50
B=1.14
Flue diameter
[in]
5.9
5.9
5.9
5.9
Compulsory flue draft
[in WC]
0.05
0.05
0.05
0.05
Tank capacity
[gal]
10.8
17.2
27.7
35.7
Dimensions, l x W x H
[in]
49.3x20.0x30.5
56.5x23.2x37.60
68.5x27.6x37.7
66.3x27.6x45.6
Net Weight
[lb]
94
176
264
330
iMpOrtant
Before using the heater, read and understand all instructions and 
follow them carefully. The manufacturer is not responsible for 
damages to goods or persons due to improper use of units.
general recOMMendatiOns
This indirect-fired heater runs on diesel fuel. Those with direct 
combustion send hot air and the combustion products into 
the room, while those with indirect combustion are fitted 
with a flue to take the fumes away through the chimney.
  Always follow local ordinances and codes when using this 
heater:
•  Read and follow this owner’s manual before using the 
heater.
•  Use only in places free of flammable vapors or high dust 
content.
•  Never use heater in immediate proximity of flammable 
materials (the minimum distance must be 6 ft.).
•  Make sure fire fighting equipment is readily available.
•  Make sure sufficient fresh outside air is provided according 
to the heater requirements. Direct combustion heaters 
should only be used in well vented areas in order to avoid 
carbon monoxide poisoning.
•  The heater is installed near a chimney to take away the 
fumes (see “Ventilation” on page 5) and connected to an 
electrical switchboard.
•  When the heater is connected to a flue pipe, the flue pipe 
shall terminate in a vertical section at least two feet long 
and sufficient draft shall be created to assure safe and 
proper operation of the heater.
•  Never block air inlet (rear) or air outlet (front).
•  In case of very low temperatures add kerosene to the 
heating oil.
•  Make sure heater is always under surveillance and keep 
children and animals away from it;
•  Before starting the heater always check free rotation of 
ventilator fan.
•  Indirect fired units only can be connected to air ducts to 
distribute warm air, with respect to the max. static pressure 
declared (see “TeCHNICAl SPeCIFICATIoN” sheet).