Gas-Fired Products PTU Series Manual De Usuario

Descargar
Página de 54
Form #43343330 
 
 
May 08 
–49– 
 
IGNITION MODULE DIAGNOSTICS 
 
 Flame Fault 
 
 
If at any time the main valve fails to close completely and maintains a flame, the full time flame sense circuit will 
detect it and energize the combustion blower. Should the main valve later close completely removing the flame 
signal, the combustion blower will power off following the post purge period. 
 Fault Conditions 
 
The LED located on the ignition module will flash ON 
for ¼ second, then OFF for ¼ second during a fault 
condition.  The pause between fault codes is 3 
seconds. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
24.0) INSTALLATION 
DATA 
 
 
Date of Installation:   
# of Heaters in System:   
Serial No.   
Model:  PTS or PTU 
 
 
N = Natural Gas 
L = Propane Gas 
 
 
Error Mode 
LED Indication 
Internal Control Failure 
Steady On 
Air Flow Fault 
1 Flash 
Gas valve failure (stuck open)  2 Flashes 
Ignition Lockout 
3 Flashes 
MULTIPURPOSE METER
USE
MICROAMP
SCALE
BLACK (-)
RED (+)
LED Display
GND
V2
FC-
FC+
V1
(W)TH
Ignition Module (Fenwal)
Flame Sensor Current Check
(R) 24VAC
L1
IND
NC
P.SW
S1