14 
 
Operator’s Manual
Operation
OPERATION
IMPORTANT:  Review  and  understand  the  warnings  in 
the Safety Information section. They are needed to safely 
operate this space heater. Follow all local ordinances and 
codes when using this space heater.
 
WARNING: FOLLOW THE MINIMUM FRESH,  
 
 
OUTSIDE AIR VENTILATION  
 
 
REQUIREMENTS. IF PROPER FRESH,  
 
 
OUTSIDE AIR VENTILATION IS NOT  
 
 
PROVIDED, CARBON MONOXIDE  
 
 
POISONING CAN OCCUR. PROVIDE  
 
 
PROPER FRESH, OUTSIDE AIR  
 
 
VENTILATION BEFORE RUNNING  
 
 
HEATER.
START SPACE HEATER:
1. Follow all ventilation and safety information.
2. Locate  heater  to  provide  maximum  circulation  of  the 
heated air. Follow all location requirements noted in the 
Safety Information section of this manual.
3. Fill fuel tank with kerosene or #1 fuel oil.
4. Attach fuel cap.
5. Set thermostat dial to desired temperature. 
Note: Thermostat setting must be higher than surrounding 
air temperature.
6. Plug power cord of heater into three-prong, grounded 
extension cord. Extension cord must be at least 6 feet 
long.
    WARNING:  USE  ONLY  A  THREE-PRONG,   
      GROUNDED  EXTENSION  CORD.  USE  CORD  
      WITH  PROPER  WIRE  SIZE  TO  ASSURE  120  
      VOLT OPERATION. (FIG. 1)
7. Plug  extension  cord  into  standard  120  volt/60  hertz, 
three-hole, grounded outlet.
8. The  motor  will  start  when  extension  cord  is  plugged 
into outlet. The heater should ignite at once. If heater 
does not ignite, restart heater. To restart heater, wait 60 
seconds, then push in flame-out control reset button. 
Flame-out control reset button is at rear of heater near 
power cord (Fig. 2).
Note: A cold heater may affect the thermostat setting. This 
thermostat is a general-heating control. It is not intended 
for precise temperature control. Adjust thermostat until 
heater cycles at the desired setting.
Note: If starting heater for first time, you may need to prime 
the pump. If equipped, slightly open bleeder valve of pump 
to allow air to escape. Quickly close valve once fuel is 
seen. Wipe up any excess fuel. If equipped with canister 
fuel filter, remove the canister bottom and fill with fuel. 
Reassemble filter. Wipe up any excess fuel. You may also 
have to do this after taking heater out of storage.
Extension Cord Size Requirement
Length of Cord:
Rated Cord:
Up to 100 feet (30.48 m)
14 AWG 
101 to 200 feet (30.78 to 60.96 m)
12 AWG 
201 to 300 feet (61.26 to 91.44 m)
10 AWG 
301 to 400 feet (191.74 to 121.92 m)
8 AWG
401 to 500 feet (122.22 to 152.40 m)
6 AWG
 (Fig. 2)
Flame-Out
Control
Reset Button
 (Fig. 1)