Page 24
20101-0-0306
FBB4 Blower Installation
Attention: Install blower assembly before connecting gas inlet 
supply line.
Note: Junction box on right side of fireplace must be pre-
wired at time of fireplace installation for use with blower 
assembly. It is recommended that an ON/OFF wall switch 
be installed that will activate the power supply to the 
furnace by a qualified electrician. See page 26 for junction 
box wiring instructions
1. If installed, turn OFF gas supply to fireplace.
2. If applicable, turn OFF electric supply to fireplace.
3. Lower bottom louver on fireplace.
Attention: If installed, do not damage gas inlet supply line when 
blower assembly is inserted into fireplace. If necessary, removal 
of the gas inlet supply line may be necessary.
4. Insert blower assembly into interior, bottom of fireplace. Position 
blower  assembly  behind  gas  valve,  align  notch  on  back  of 
blower assembly with center screw on fireplace back and push 
blower assembly against fireplace back. The blower wheel must 
be centered with the back wall of the fireplace. Place blower 
assembly against the back wall. The magnets on the back and 
bottom of blower assembly will sufficiently hold blower assembly 
in place.
5. Position speed control box to the right of gas valve. Attach speed 
control box to bottom of fireplace. The magnets on the bottom 
of speed control will sufficiently hold the speed control box in 
place. 
6. With base (flush face) of fan control switch facing upward, insert 
base flanges of fan control switch under the mounting tabs on 
valve bracket. The base (flush face) of fan control switch must 
be in contract with bottom of the firebox.
7. Insert power cord plug into junction box.
8. Close bottom louver on fireplace.
Note: This blower is equipped with a heat activated fan control 
switch. Fan will operate when the fireplace warms up, and will 
turn off when the fireplace cools down.
9. Installation of FBB4 optional variable speed blower assembly 
is completed.
Figure 19
VALVE BRACKET
FAN SWITCH
FAN KIT
SPEED CONTROL
JUNCTION BOX
SWITCH HOLDER
(TOP OF VALVE BRACKET)
SEE NOTE
OPTIONAL BLOWER
I N S T A L L AT I O N I S
I N T E N D E D F O R
LOUVERED MODELS
ONLY.