Hampton Direct H35-NG1 Manual De Usuario

Descargar
Página de 48
Hampton
®
 H35 Direct Vent Freestanding Gas Stove
31
CONVERSION KIT TO LOWER BTU RATING
NATURAL GAS - KIT #: 740-950   PROPANE - KIT # 740-952
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER
IF IN DOUBT DO NOT DO THIS CONVERSION !!
Natural Gas Conversion Kit 740-950  Contains:
Qty. Part # 
Description
904-240 
Burner Orifi ce #37 (Natural Gas)
918-034 
Decal "Converted to 30,000 Btu"
1 918-148 Instruction 
Sheet
Propane Conversion Kit 740-952  Contains:
Qty. Part # 
Description
1 904-390 Burner 
Orifi 
ce 
#52 
(Propane)
918-149 
Decal "Converted to 28,500 Btu"
1 918-148 Instruction 
Sheet
1)  Shut off the gas supply.
2)  Open the front door.  Carefully remove the logs and lava rock. (Refer 
to manual for more detailed instructions.)
3)  Remove burner by removing 2 screws, sliding the burner to the left 
and lift out. See diagram below.
Burner Orifi ce
Note: Use a magnetic type screwdriver if possible.
4)  Remove Rear Log Bracket by removing 2 screws. See diagram 
below.
5)  Unscrew the 2 Rear Log Pins and move to the front hole position.
6)  Reinstall Rear Log Bracket.
7)  Remove burner orifi ce  with a 1/2" wrench and discard.
8)  Reinstall new burner orifi ce (NG stamped #37 or LP stamped #52) 
and tighten.
9)  Reverse steps 3) and 2).
INSTALLATION