State of Massachusetts: The installation 
must  be  made  by  a  licensed  plumber 
or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
Sellers  of  unvented  propane  or  natural 
gas-fired  supplemental  room  heaters 
shall provide to each purchaser a copy of 
527 CMR 30 upon sale of the unit.
Vent-free gas products are prohibited for 
bedroom  and  bathroom  installation  in 
the Commonwealth of Massachusetts.
ProdUCT FeATUres
OpERATION
This firebox is designed for use with approved 
ANSI Z21.11.2 decorative type unvented room 
heaters. (Physical size limitations apply. Refer 
to  minimum  firebox  requirements  supplied 
with log heater.) It requires no outside vent-
ing or chimney making installation easy and 
inexpensive.
loCAl Codes
loCATINg FIreBoX
pLANNING
Plan where you will install the firebox. This will 
save time and money later when you install 
the firebox. Before installation, consider the 
following:
1.  Where firebox will be located. Allow for 
wall and ceiling clearances (see Installa-
tion Clearances, page 11).
2.  Everything needed to complete installation.
3.  These  models  CANNOT  be  installed  in 
a  bedroom  unless  maximum  Btu  rating 
of installed vent-free log set is less than 
10,000 Btu/hr.
4.  Proper air for combustion and ventilation 
(page 8).
Install and use firebox with care. Follow all 
local codes. In the absence of local codes, 
use the latest edition of The National Fuel Gas 
Code ANSI Z223.1/NFPA 54*. Firebox must 
be electrically grounded in accordance with 
the National Electrical Code, ANSI/NFPA70 
(latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY  10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA  02269