5.  Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information in column 1. If you don’t
smell gas, go to the next step.
6.  The pilot is located by the main burner and
should not require accessing for lighting.
7.  Turn gas control knob counterclockwise
to PILOT.
8.  Push in gas control knob all the way and
hold. Immediately light pilot by repeatedly
depressing piezo spark ignitor until a flame
appears. Continue to hold for about 1 min-
ute after pilot is lit. Release gas control knob
and it will pop back. Pilot should remain
lit. If it goes out, repeat steps 4 through 7.
• If gas control knob does not pop up when
released, stop and immediately call our
service technician or gas supplier.
• If pilot will not stay lit after several tries,
turn gas control knb to OFF and call your
service technician or gas supplier.
9.  Turn on all electric power to the fireplace.
10.  Turn gas control knob counterclockwise
to ON.
11.  This valve is equipped with a HI/LO fea-
ture. Set fireplace input as desired.
12.  Close lower louver panel.
OPERATING FIREPLACE
FOR YOUR SAFETY 
READ BEFORE LIGHTING
 WARNING: If you do not fol-
low  these  instructions  exactly, 
a  fire  or  explosion  may  result 
causing property damage, per-
sonal injury or loss of life.
A.  This appliance is equipped with an ignition
device which automatically lights the pilot.
Do not try to light by hand.
B.  BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
 WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately  call  your  gas  supplier
from a neighbor's phone. Follow the gas
supplier's instructions.
C.  Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand,
don't try to repair it, call a qualified service
technician. Force or attempted repair may
result in a fire or explosion.
D.  Do not use this appliance if any part has
been  under  water.  Immediately  call  a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING 
INSTRUCTIONS
NOTICE: During initial operation of 
new heater, burning logs will give 
off a paper-burning smell. Orange 
flame will also be present. Open 
damper or window to vent smell. 
This will only last a few hours.
1.  STOP!  Read  the  safety  information,
above.
2.  Open lower louver panel.
3.  Turn off all electric power to the fireplace.
4.  Push in gas control knob slightly and turn
clockwise
to OFF.
TO TURN OFF GAS 
TO AppLIANCE
1.  Open lower louver panel.
2.  Set selector switch in the OFF position to
prevent draining battery.
3.  Turn off all electrical power to the appliance
if service is to be performed.
4.  Push in gas control knob slightly and turn
clockwise
to OFF.
5.  Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot
lit by doing one of the following:
1.  Turn gas control knob clockwise
 
to the PILOT position.
2.  Set selector switch in the OFF position.
O
F
  PILOT   
LO 
IH 
O
N
     
    
    
   
Figure 50 - Control Valve
Piezo 
Ignitor
Gas Control 
Knob
Variable Control Knob