Desa (V)T32P SERIES Manual De Usuario

Descargar
Página de 40
www.desatech.com
111986-01D
30
INSPECTING bURNERS
Check pilot flame pattern and burner flame pat-
terns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper 
flame height. Alterations may have occurred dur-
ing shipping and handling. Call a qualified service 
person to readjust the pilot if necessary.
The height of the thermopile must be 3/8" to 1/2" 
above pilot flame as shown if Figure 54. The 
thermocouple must be at a height of about 1/8" 
above the pilot flame. The flame from the pilot 
burner must extend beyond both the thermocouple 
and thermopile.
If your pilot assembly does not meet these re-
quirements:
•  turn fireplace off (see To Turn OFF Gas to Ap-
pliance, page 25)
•  see Troubleshooting, page 32
BURNER FLAME PATTERN
Burner flames will be steady; not lifting or floating. 
Flame patterns will be different from unit to unit 
and will vary depending on installation type and 
weather conditions.
If the vent configuration is installed incorrectly, 
the flames will lift or "ghost". This can be danger-
ous. Inspect the flames after installation to ensure 
proper installation and performance. 
Figure 55 shows a typical flame pattern. 
If burner flame pattern differs from that described:
•  turn fireplace off (see To Turn Off Gas to Ap-
pliance, page 27)
•  see Troubleshooting, page 32
Figure 55 - Typical Flame Pattern
Thermocouple
Thermopile
1/8"
Pilot Burner
Piezo 
Ignitor
Figure 54 - Pilot Assembly
3/8" to 1/"
CLEANING AND 
MAINTENANCE
 WARNING: Turn off fireplace 
and let cool before cleaning.
  CAUTION:  You  must  keep 
control  areas,  burners,  and 
circulating air passageways of 
fireplace  clean.  Inspect  these 
areas  of  fireplace  before  each 
use.  Have  fireplace  inspected 
yearly  by  a  qualified  service 
person.  Fireplace  may  need 
more frequent cleaning due to 
excessive  lint  from  carpeting, 
bedding material, pet hair, etc.
GLASS DOOR
  WARNING:  Handle  glass 
door  panel  with  care.  Do  not 
strike, slam, or otherwise abuse 
glass. Do not operate fireplace 
with  the  glass  door  removed, 
cracked, or broken.
 WARNING: Do not use abra-
sive cleaners as this may damage 
glass. Use a nonabrasive house-
hold glass cleaner to clean glass. 
Do not clean glass when hot.
Glass must be cleaned periodically. During start-
up it is normal for condensation to form on the 
inside of the glass causing lint, dust, and other 
airborne particles to cling to the glass surface. 
During initial start-up a slight film may form on 
the glass due to paint curing. The glass should be 
cleaned several times with a non-ammonia, non-
abrasive household cleaner and warm water after 
the first two weeks of operation. Thereafter, clean 
the glass two or three times during each heating 
season, depending on the usage and circumstances 
present. Refer to Removing/Replacing Glass Door 
on page 24 of this manual when removing glass 
door for cleaning.