Figure 2 - Common Fireplace Locations
Flush with a wall
Through exterior wall 
enclosed in a chase
Corner 
installation
•  This fireplace does not require electricity to 
operate.
•  Only the blower requires electricity if installed 
and if you plan to install the blower at a later 
date, do not forget to wire the outlet at the bot-
tom of the fireplace when framing.
•  A piezo ignitor and ceramic electrode create 
spark to ignite the pilot light. It does not require 
any matches, batteries or any other sources of 
ignition to light the pilot.
•  Each time you turn on your fireplace, you may 
notice some amount of condensation on the 
inside of the fireplace glass. This is normal and 
will disappear after 10-20 minutes of opera-
tion.
•  Your direct-vent gas fireplace system (fireplace 
and venting) is a balanced and sealed gas op-
erating unit. It requires approximately 10-20 
minutes of operating time before the flame 
pattern stabilizes.
PRE-INSTALLATION 
PREPARATION
LOCATION AND SpACE 
REqUIREMENTS
Determine the safest and most efficient location 
for your DESA direct-vent fireplace. Make sure 
that rafters and wall studs are not in the way of the 
venting system. Choose a location where the heat 
output is not affected by drafts, air conditioning 
ducts, windows or doors. Figure 2 shows some 
common locations. Be aware of all restrictions and 
precautions before deciding the exact location for 
your fireplace and termination cap.
When deciding the location of your fireplace, 
follow these rules:
•  Do not connect this fireplace venting to a chim-
ney flue serving a separate solid-fuel burning 
fireplace or appliance.
•  Due to high temperatures, do not locate this 
fireplace in high traffic areas, windy or drafty 
areas or near furniture or draperies.
•  Proper clearances must be maintained.
•  If your fireplace is to be installed directly on 
carpeting, vinyl tile or any combustible mate-
rial other than wood, it must be installed on a 
metal or wood panel extending the full width 
and depth of the fireplace. See Figure 3.
•  Your fireplace is designed to be used in zero clear-
ance installations. Wall or framing material can be 
placed directly against any exterior surface on the 
back, sides or top of your fireplace, except where 
standoff spacers are integrally attached. If standoff 
spacers are attached to your fireplace, these spac-
ers can be placed directly against wall or framing 
material. See framing details on page 6.
•  If you plan on installing a television or enter-
tainment center recessed above your fireplace, it 
is recommended that you maintain a minimum 
18" above top of louver opening.
•  When locating termination cap, it is important 
to observe the minimum clearances shown in 
Figure 7, page 7.
•  If recessing into a wall, you can avoid extra 
framing by positioning your fireplace against 
an already existing framing member.
•  Do not recess termination cap into a wall or 
siding.
•  You may paint the termination cap with 450º F 
(232º C) heat-resistant paint to coordinate with 
the exterior finish. 
•  There must not be any obstruction such as bushes, 
garden sheds, fences, decks or utility buildings 
within 24" from the front of the termination cap.
•  Do not locate termination cap where excessive 
snow or ice build up may occur. Be sure to 
clear vent termination area after snow falls to 
prevent accidental blockage of venting system. 
When using snow blowers, do not direct snow 
towards vent termination area.
Figure 3 - Fireplace Bottom Dimensions
D
RW
FW
34 
3
/
8
"
 
1
/
"
16 
5
/
8
"