Fireplace inSTallaTion
SELECTING LOCATION
To determine the safest and most efficient location 
for the fireplace, you must take into consideration 
the following guidelines:
1.  The location must allow for proper clearances 
(see Figures 1 and 2).
2.  Consider a location where the fireplace will 
not be affected by drafts, air conditioning 
ducts, windows or doors.
3.  A location that avoids the cutting of joists or 
roof rafters will make installation easier.
4.  An outside air kit is available with this fireplace 
(see Optional Outside Air Kit on page 6).
MINIMUM CLEARANCE TO 
COMBUSTIBLES
Back and sides of fireplace  1 
1
/
2
" min.*
Front of fireplace 
48" min.
Floor** 
0" min.
Perpendicular wall to opening  12" min. 
Top spacers 
0" min.
Mantel clearance 
see Mantels, page 5
Chimney outer pipe surface  1" min. 
* Not required at nailing flanges
** See step 2 of Framing
 WARNING: Do not pack re-
quired air spaces with insulation 
or other materials.
Minimum/Maximum Chimney Height
The minimum height of the chimney, measured 
from the base of the fireplace to the flue gas outlet 
of the termination, is 16 feet for straight flue or a 
flue with one elbow set. The maximum distance be-
tween elbows is 6 feet. For systems with two elbow 
sets, the minimum height is 22 feet. The maximum 
height of any system is 50 feet. This measurement 
includes the fireplace, chimney sections and the 
height of the termination assembly at the level of 
the flue gas outlet (see Figure 15, page 9).
FRAMING
1.  Frame the opening for the fireplace using the 
dimensions shown in Figures 1 and 2.
2.  If the fireplace is to be installed directly on 
carpeting, tile (other than ceramic) or any 
combustible material other than wood floor-
ing, the fireplace must be installed upon a 
metal or wood panel extending the full width 
and depth of the fireplace.
3.  Set the fireplace directly in front of this open-
ing and slide the unit back until the nailing 
flanges touch the side framing.
4.  Check the level of the fireplace and shim with 
sheet metal if necessary.
5.  Before securing fireplace to prepared framing, 
the ember protector (provided) must be placed 
between the hearth extension (not supplied) 
and under the bottom front edge of the fire-
place to protect against glowing embers falling 
through. If the fireplace is to be installed on 
a raised platform, a Z-type ember protector 
(not supplied) must be fabricated to fit your 
required platform height. The ember protector 
should extend under the fireplace a minimum 
of 1 
1
/
2
". The ember protector should be made 
of galvanized sheet metal (28 gauge minimum 
to prevent corrosion.
6.  Using screws or nails, secure the fireplace to 
the framing through flanges located on the 
sides of the fireplace.
28.25"
58.125"
67.125"
45.25"
Figure 1 - Framing Dimensions
86.5"
61"
Maintain 1
1
/
2
"
Clearance at Sides
and Back of Fireplace
1
1
/
2
" Clearance
Not Required at 
Nailing Flanges 
Figure 2 - Corner Installation