Winterizing (Continued) 
 
To Winterize a Heat Pump Equipped with an External Drain 
(Per Figure-3) 
 
1.  Disconnect all electrical power to the heater; turn OFF circulating pump.  
2.  At the two (2) connection unions, disconnect the plumbing to the heater 
(removal is counter-clockwise).   
3.  Locate the drain plug at lower, right-hand, front corner of heater. See Figure-3. 
4.  Using a 5/8”, box-end wrench, remove the drain plug (removal is counter-
clockwise). 
5.  Permit all of the water to drain out of the condenser, and then replace the plug:   
thread the plug in clockwise until just snug, then apply an additional 1/8 turn. 
6.  To prevent insects and vermin from entering the plumbing during the 
winterized period, partially reconnect the two (2) plumbing connection unions: 
couple each union one or two threads; this will permit condensation to drain, 
but will prevent most insects and animals from entering the plumbing circuit. 
7.  Next Season: to ready the heat pump for use, simply re-tighten plumbing 
connection unions.  Hand-tight is generally sufficient.