Haier HSU18VH7 Manual De Usuario

Descargar
Página de 27
- 8 - 
Air conditioner
Edition: 10070808
     
temperature, sleep state, flap state. 
              .  Cancellation  of  function:  Pressing  the  SLEEP  button  on  the  remote 
control unit for 10 times until hearing 2 sounds from the buzzer on the 
panel.   
 Trial run function 
When  the  air  conditioner  is  in  OFF  state,  press  the  emergency  switch  for  5 
seconds till hearing 2 sounds of click from the buzzer, then the air conditioner will 
turn  to  the  trial  run  state.  The  unit  will  run  in  the  refrigerating  mode  and  the 
indoor fan will run in high wind speed mode.   
 
 Emergency running mode 
When  the  air  conditioner  is  in  stand-by  state,  press  the  emergency  switch  till 
hearing  a  sound  from  the  buzzer,  then  the  air  conditioner  will  turn  to  the 
emergency run state. The rules of emergency run are as follows: 
a. Tr≥23℃, running refrigerating mode, Ts = 26℃; 
b. Tr<23℃, running heating mode, Ts = 23℃. 
 Temperature compensation. 
There is the function of automatic temperature compensation when heating, with 
heating temperature setting = Ts(remote setting) + 4℃. 
Sleeping function 
a. After setting the sleeping function, the refrigerating mode and dehumidification 
mode will run as per the following rules:
                                                                                                             
                                                                          6hours 
                T(℃) 
                                          1 hour               
              Ts+2                                               
                Ts+1    1 hours                                   
                                                             
                                                                             
                      Ts       
  Sleep
                                                        OFF                t(hour) 
b. After  setting  the  sleeping  function,  the  heating  mode  will  run  as  per  the 
following rules:
 
            T(℃)       
                  Ts                                    3hours                  3hours 
                                     
                Ts-2                 
                Ts-3               
                Ts-4           
                          1 hour 
 
As shown in the above diagram, after running for 1 hour under refrigerating mode and 
dehumidification mode, the setting temperature will increase 1
; after 
 
c
3.2.11
3.2.12
3.2.13
3.2.14