Haier HSU-09HSA03/R2(DB) Manual De Usuario

Descargar
Página de 90
Haier air conditioner
Edition: 20070116 
- 46-
F11: The malfunction of the compressor’ rotor circuit
The IPM might be broken, 
replace it with a new one.
The Malfunctions exist also. The
compressor is damaged replace 
a new one
1. The wiring of compressor is 
incorrect or the connection is 
poor;
2. The compressor is damaged
Within 3 minutes after the machine is 
supplied with power and turned on with 
the remote controller, the outdoor unit 
stops shortly after startup, and the 
compressor will start up again 10 
seconds after the machine stops. The 
above process repeats again and 
again.
At the stopped state, LED2 on 
the outdoor PCB blinks
˄1Hz˅for
several times, and after pause of
2 seconds or so, it blinks for the 
same times again.
No
Yes
Yes
Malfunction
unsolved