Heat Controller BD-101 Manual De Usuario

Descargar
Página de 35
—22—
Do not under any 
circumstances cut 
or remove the 
grounding prong 
from the plug.
Line Cord Plug
Use Wall Receptacle
Power Supply
Power supply cord with
3-prong grounding plug
Standard 125V, 3-wire grounding
receptacle rated 15A, 125V AC
Parallel
type
Use 15 AMP time
delay fuse or 15 AMP
circuit breaker.
Line Cord Plug
Use Wall Receptacle
Power Supply
Do not under any 
circumstances cut 
or remove the 
grounding prong 
from the plug.
Power supply cord with
3-prong grounding plug
Tandem
type
Perpendicular
type
Standard 250V, 3-wire grounding
receptacle rated 15A, 250V AC
Use 15 AMP
time delay fuse or
circuit breaker.
Use 20 AMP
time delay fuse or
circuit breaker.
Refer to the nameplate
for correct fusing.
Do not under any 
circumstances cut 
or remove the 
grounding prong 
from the plug.
Power supply cord with
3-prong grounding plug
Standard 250V, 3-wire grounding
receptacle rated 20A, 250V AC
USE OF EXTENSION CORDS
Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish
to use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125V.
3.4.1 ELECTRICAL  DATA (FOR 115V MODEL)
3.4.2 ELECTRICAL  DATA (FOR 230/208V MODEL)
3.4.3 ELECTRICAL SAFETY 
All wiring should be made in accordance with local electrical codes and regulations.
NOTE : Aluminum house wiring may pose special problems. Consult a qualified electrician. 
IMPORTANT GROUNDING INSTRUCTIONS
Air conditioner has a three-prong grounding plug on its power supply cord, which must be plugged into properly grounded
three-prong wall receptacle for your protection against possible shock hazard. 
FUSE – Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements. 
208, 230, and 208/230 VOLT UNITS
These units are equipped with a three-prong grounding plug on the power supply cord, which must be plugged into a matching
properly grounded three-prong wall receptacle for your protection against possible shock hazard. If such an outlet is not
present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and
ordinances. 
NOTE: DO NOT USE AN EXTENSION CORD on 208, 230, and 208/230 Volt units.
3.4 ELECTRICAL REQUIREMENTS