10.4 Tubing Length
Install unit within the maximum elevation
different (H) above or below the outdoor 
unit  and within a tatal tubing length (L) 
from the outdoor unit as detailed showed 
in Table 4 and Fig.37.
INDOOR
UNIT
Tubing length (L)
OUTDOOR
UNIT
Elevation
difference (H)
Fig. 37
10.5 Accessories
Table 5 listed the accessories supplied with the unit.
Table 4
*1 Standard tubing length is 5.0m.
*2 If total tubing length becomes 5.0m to 20 or 25 or 30m, charge additional refrigerant (R22) according  
    to table 4 above. No additional charge of compressor oil is necessary.
Model
Max. Allowable Tubing
Length at Shipment
(m)*
1
Limit of Tubing
Length (L)
(m)
Limit of Elevation
Different (H)
(m)
Required Amount of 
Additional Refrigerant
(g/m)*
2
C18AP
5.0
7
30
25
C25AP
5.0
7
30
30
10. INSTALL OUTDOOR UNIT
Installation Service
C30AP
5.0
15
50
30
C12AP
5.0
5
20
20
Table 5 
Parts
Figure
Q’ty
Parts
Figure
Q’ty
Tapping
Screw
AAA alkaline
battery
2
Remote
Control Unit
5
1
1
10
Putty
1
4.2 x 25 mm
1
1
Ins. Tube
FAN
OPER
ON
OFF
C
ON
/OFF
F
A
N
-
+
MODE
CLOCK
TIM
ER
 O
N
BLOW
TEMP
TIM
ER O
FF
TURBO
SLEEP
LIGHT
Power
Connection 
Wire
0
Flare Nut
1
Power
Supply
Wire
*(K30AP only)
Model: 
K9AP,K12AP
Models: 
K18AP, K25AP, K30AP
1
Remote Control
Holder
(Optional)
*Only for specified model.
C9AP
5.0
5
20
15
*(K9AP, K12AP only)