7. NOTICES FOR INSTALLATION
                
1. The unit installation work must be done by qualified
    personnel according to the local rules and this manual.
2. Before install, please contact with local authorized 
    maintenance center. If the unit is not installed by the 
    authorized maintenance center, the malfunction may 
    not solved, due to discommodious contacts.
3. When removing the unit to the other place, please
    firstly contact with the authorized SANYO Maintenance 
    Center in the local area.
Install in the following place may cause malfunction. If it 
is unavoidable contact with service center please: 
1. Place where strong heat sources, vapors, flammable gas or 
    volatile object are emitted.
2. Place where high-frequency waves are generated by radio 
    equipment, welders and medical equipment. 
3. Place where a lot of salinities such as coast exists.
4. Place where a sulfured gas such as the hot spring zones is 
    generate.
5. Place where the oil (machine oil) is contained in the air.
6. Other place with special circumstance.
1. The air inlet and outlet vent should be far from the 
    obstruction, make sure that the air can be blown through 
    the whole room.
2. Select a position where the condensing water can be easily 
    drained out, and the places easily connected for outdoor 
    unit.
3. Select a location where the children can not reach.
4. Can select the place where is strong enough to withstand 
    the full weight and vibration of the unit. And will not increase 
    the noise.
5. Be sure to leave enough space to allow access for routine     
    maintenance. The height of installed location should be     
    200cm or more from the floor.6. Select a place about 1m or 
    more away from TVset or any other electric appliances. 
7. Select a place where the filter can be easily taken out.
8. Make sure that the indoor unit installation should accord 
    with installation dimension diagram requirements. (Pg.24) 
1. Select a location from which noise and outflow air emitted 
    by unit will not inconvenience neighbours, animals, plants.
2. Select a location with sufficient ventilation.
3. Select a location where there should be no obstructions
    cover the inlet and outlet vent.
4. The location should be able to withstand the full weight and 
    vibration of the outdoor unit and permit safe installation.
5. Select a dry place, but do not expose under the direct     
    sunlight or strong wind.
7.1 Basic Requirements 
      for Installation 
      Position 
7.2 Indoor Unit 
      Installation Position 
      Selection 
7.3 Outdoor Unit 
      Installation
      Position Selection 
Important Notices