10
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
(3) Outdoor unit CH1852
Control PCB
Part No.
POW-CH095
Controls
Control circuit fuse
Compressor
Type
Rotary (Hermetic)
Compressor model
C-R132H6D
Nominal output
W
1,300
Compressor oil … Amount
cc
SUNISO 4GSD-T … 500
Coil resistance (ambient temp. 68°F (20°C))
Ω
C – R: 1.442
C – S: 2.430
Safety devices
Type
External (OLR)
Overload relay
MRA99117-9200
Run capacitor
µF
35
VAC
400
Crank case heater
230V, 20W
Heat Exchanger Coil
Coil
Aluminum plate fin / Copper tube
Rows
2
Fin pitch
inch (mm)
1/16 (1.6)
Face area
ft
2
(m
2
)
5.13 (0.477)
External Finish
Acrylic baked-on enamel finish
Fan & Fan Motor
Type
Propeller
Q’ty … Dia. and length
inch. (mm)
1 … 16-17/32 (ø 420)
Fan motor model … Q’ty
KFG6-51E6PA … 1
No. of poles … rpm (230V, High)
6 … 830
Nominal output
W
50
Coil resistance (ambient temp. 68°F (20°C))
Ω
WHT – BRN: 102
PNK – WHT: 199
Run capacitor
µF
2
VAC
440
000-111 
SM 
(1-17) 
 
00.3.17 
11:44 
AM 
  y [ W  10