APPENDIX A BLOWER PERFORMANCE TABLES
DIRECT DRIVE
STANDARD CPC/H060 DOWN SHOT
 SPEED
TAP 
 EXTERNAL STATIC 
PRESSURE (ESP)
in w.c. 
 STANDARD
C FM 
 AMPS 
  WATTS 
 RPM 
0. 10
1334
1.65
180
627
0. 20
1286
1.75
192
665
0. 30
1212
1.83
202
715
0. 40
1144
1.94
216
759
0. 50
1077
1.99
222
792
0. 60
1039
2.10
238
830
0. 70
953
2.17
248
874
0. 80
904
2.27
258
913
0. 90
825
2.30
266
940
0. 10
1512
2.12
240
682
0. 20
1469
2.24
254
720
0. 30
1397
2.31
264
759
0. 40
1333
2.44
282
803
0. 50
1285
2.54
296
836
0. 60
1221
2.59
304
874
0. 70
1173
2.72
322
913
0. 80
1118
2.77
328
946
0. 90
1049
2.90
344
984
0. 10
2053
4.27
540
869
0. 20
2014
4.39
558
896
0. 30
1999
4.60
576
929
0. 40
1947
4.68
588
957
0. 50
1897
4.79
608
989
0. 60
1857
4.87
620
1012
0. 70
1763
4.99
640
1050
0. 80
1741
5.06
650
1072
0. 90
1669
5.19
668
1105
0. 10
2137
4.95
634
913
0. 20
2093
5.07
652
940
0. 30
2095
5.19
670
962
0. 40
2026
5.28
682
990
0. 50
1980
5.40
698
1018
0. 60
1961
5.49
720
1039
0. 70
1914
5.58
732
1072
0. 80
1845
5.70
742
1100
0. 90
1766
5.69
740
1127
0. 10
2299
5.70
742
942
0. 20
2233
5.80
748
969
0. 30
2217
5.90
768
990
0. 40
2157
6.07
786
1018
0. 50
2131
6.12
804
1045
0. 60
2060
6.21
816
1073
0. 70
2015
6.30
820
1095
0. 80
1940
6.27
816
1111
0. 90
1862
6.13
790
1128
NOTES:
T5
CPC/H060 DIRECT DRIVE DOWN SHOT
Tab les represent dry coil without filter, to compensate for filter add 0.08" to measured E.S.P. SCFM 
correction for wet coil = 4 %.  5 T on models are shipped from the factory with speed tap set on T4.
T1
T2
T3
T4