Goodman Mfg 000 &12 Manual De Usuario
4
NOTE:
Install the mounting bracket and drill the holes in the
wall according to the wall structure and the correspond-
ing mounting points on the mounting bracket. (The
mounting brackets vary according to the model.)
ing mounting points on the mounting bracket. (The
mounting brackets vary according to the model.)
Incorrect orientation
of Installation Plate
of Installation Plate
Correct orientation
of Installation Plate
of Installation Plate
Figure 4
4. Determine the hole positions according to the diagram
detailed in Figures 5A & 5B. Drill one (1) 2.5” hole ( 65mm),
slanting slightly to the outside.
slanting slightly to the outside.
NOTE:
Always use wall hole conduit when drilling metal
grid, metal plate, etc.
Model B (A: 31” (790mm), B:10” (265mm), C:4” (100mm), D: 6” (151mm)
C
D
Figure 5A
7” (187mm)
6” (150mm)
Figure 5B
Refrigerant Piping & Condensate Piping
Installation:
5. Drain hose should be installed with a slight downward
slope. (See Figure 6.)
Wall
Indoor
Outdoor
5-
7m
m
3/
1
6
” -
1
/4
”
Figure 6
Do NOT install drain hose as shown in Figure 7.
Do not block water flow by a rise.
Do not put the end of
drain hose into water.
Figure 7
6. When connecting extension drain hose, insulate the con-
necting part of the extension drain hose with a shield
pipe. Do not allow the drain hose to be slack.
pipe. Do not allow the drain hose to be slack.
7. REFRIGERANT PIPING INSTALLATION:: For the left-
hand and right-hand piping, remove the pipe cover from
the side panel. (Figure 8.)
the side panel. (Figure 8.)
Figure 8
8. For the rear right-hand and rear left-hand piping, install as
shown in Figure 9.
Figure 9
To make refrigerant tube connections, refer to Tightening
Connection in the Refrigerant Piping Connection.
Connection in the Refrigerant Piping Connection.