Won’t cool
If the unit operates, but won’t cool, determine if the controls are 
properly set. Wait three minutes before setting the ther mo stat to a 
cooler position in order to check control settings. Check the fi lter and 
clean it thoroughly, if needed. Check to see if the vent door is closed. 
Check to see if the chassis seal gasket is properly installed (refer to 
page 14 for seal gasket installation).
Won’t heat (for heat/cool models only)
If the unit operates, but won’t heat, determine if the control settings are 
correct. Adjust the ther mo stat to a warmer position to determine if it 
operates. Also, check the fi lter and clean it thor ough ly, if needed.
Odors in heating (for heat/cool models only)
You may notice a smoke odor the fi rst time the heater element comes 
on. This is common in any type of heat system when fi rst turned on 
for the winter. The odor comes from dust and other particles that 
accumulate during the warm months. The odor will dissipate quickly.
Won’t run
If the unit fails to operate, check to see if the power cord is fi rmly 
plugged in. Check for blown fuses, tripped circuit breakers or a 
tripped LCDI Device (Refer to LCDI reset instructions in the Power 
cord information 
section). Restore the circuit breaker or replace the 
blown fuse with a proper size "TIME-DELAY" fuse. The proper fuse 
size is shown on pages 4 and 7 in these instructions. After restoring 
the current supply to the unit, wait three minutes before restarting.
Things to know about a WallMaster heat pump
During the heat pump operation, you may notice some functions that did not occur when the unit was used for cooling:
 1.  It is common for ice to form on the outdoor coil of your WallMaster Heat Pump. The ice forms due to moisture in the outdoor 
air passing over cold (below freezing) coil surfaces.
2.  When the outdoor coil forms ice, your heat pump will automatically initiate a defrost. The com pres sor will stop and the fan will 
continue to run. The electric heat will be turned on to continue warming the room while the outdoor air defrosts the outdoor 
coil.  After the defrost is completed, the unit will automatically return to the heat pump mode.
3.  It is normal for vapor (steam) to rise from the outdoor coil during the defrost. This is similar to expelling warm breath on a 
cold morning.
4.  If the outdoor temperature drops below 43°F during heat pump op er a tion,  your  WallMaster  Heat  Pump  will  au to mat i cal ly 
switch to electric re sis tance heat and will continue to operate in this mode as long as the outdoor tem per a ture remains at 
43°F or below.
Frosting of the indoor coil
Certain operating conditions may produce indoor coil frost. During 
the cooling operation, a dirty fi lter or restricted air distribution in 
combination with cool, damp weather could cause such an occurrence. 
Should the indoor coil frost over while cooling, set the control to FAN 
and keep it running until the frost on the coil is gone. Setting the 
ther mo stat to a slightly warmer position will probably keep the coil 
from frosting over again.
Cleaning the decorative front
The decorative front of your Friedrich room air conditioner, as well 
as the complete cabinet, may be cleaned with warm water and mild 
detergent. Under adverse operating con di tions, the indoor and outdoor 
coils and base pan may require periodic cleaning to maintain ef fi  cient 
operation.  Your Friedrich dealer should be called when this service 
is required.
Troubleshooting tips and home maintenance