Friedrich CP05C10 Manual De Usuario

Descargar
Página de 24
1. PREFACE 
This service manual provides various service information, including the mechanical and electrical parts, etc. 
This room air conditioner was manufactured and assembled under a strict quality control system. 
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit. 
1.1 FEATURES
•  DESIGNED FOR COOLING ONLY 
•  BUILT-IN ADJUSTABLE THERMOSTAT
•  WASHABLE ONE-TOUCH FILTER
•  COMPACT SIZE  
1.2 SPECIFICATIONS 
MODELS
ITEMS
COOLING CAPACITY (BTU/h)
5,100
POWER SUPPLY (Phase, V, Hz)
1ø, 115V, 60HZ
INPUT (W)                                                                                               520
OPERATING CURRENT (AMP.)
 
4.4
REFRIGERANT CONTROL
CAPILLARY TUBE 
REFRIGERANT CHARGE (R-22)
330g (11.6 oz)
INSIDE FAN
TURBO FAN 
OUTSIDE FAN
PROPELLER FAN WITH SLINGER RING
AIR DISCHARGE
2-WAY (RIGHT AND LEFT)
CHASSIS
TOP-DOWN
PROTECTOR 
TEMPERATURE CONTROL
THERMISTOR
FAN MOTOR
6 POLES, 21W
• OVERLOAD PROTECTOR FOR COMPRESSOR
• INTERNAL PROTECTOR FOR FAN MOTOR