HEATING SPECIFICATIONS
capacity
 btuh
c.o.p.
4.8
9.6
14.4
19.2
65
22.63
4.23
39.008
55.391
71.7732
88.156
60
21.42
4.09
37.802
54.185
70.5672
86.950
55
20.16
3.93
36.542
52.925
69.3072
85.690
50
18.85
3.75
35.228
51.611
67.9932
84.376
45
17.44
3.54
33.824
50.207
66.5892
82.972
40
16.20
3.36
32.582
48.965
65.3472
81.730
35
14.94
3.16
31.322
47.705
64.0872
80.470
30
13.55
2.88
29.933
46.315
62.6975
79.080
25
12.51
2.72
28.889
45.271
61.6535
78.036
20
11.52
2.56
27.899
44.281
60.6638
77.046
15
10.47
2.39
26.855
43.237
59.6198
76.002
10
9.40
2.19
25.778
42.161
58.5432
74.926
5
8.33
1.99
24.713
41.095
57.4775
73.860
0
7.26
1.78
23.647
40.029
56.4117
72.794
-5
6.20
1.56
22.581
38.964
55.346
71.728
-10
5.08
1.31
21.461
37.843
54.2258
70.608
Capacity of Unit
 With KW of Auxiliary heat 
Outdoor 
Ambient 
   °F.
Model: GHS140181A* / CA*F3131B6A*+TXV / MBR800**-1
Condition: 600 CFM Indoor Air @ 70°F DB
Basic Unit without 
Auxiliary Heat
capacity
 btuh
c.o.p.
4.8
9.6
14.4
19.2
65
30.17
4.30
46.550
62.933
79.315
95.698
60
28.56
4.14
44.942
61.325
77.707
94.090
55
26.88
3.98
43.262
59.645
76.027
92.410
50
25.13
3.79
41.510
57.893
74.275
90.658
45
23.26
3.58
39.638
56.021
72.403
88.786
40
21.60
3.39
37.982
54.365
70.747
87.130
35
19.92
3.19
36.302
52.685
69.067
85.450
30
18.76
2.91
35.146
51.528
67.911
84.293
25
17.32
2.74
33.700
50.083
66.465
82.847
20
15.95
2.58
32.330
48.712
65.095
81.477
15
14.50
2.40
30.884
47.267
63.649
80.031
10
13.01
2.21
29.393
45.776
62.158
78.541
5
11.54
2.00
27.918
44.300
60.682
77.065
0
10.06
1.79
26.442
42.824
59.207
75.589
-5
8.58
1.57
24.966
41.348
57.731
74.113
-10
7.03
1.32
23.415
39.797
56.180
72.562
C apacity of Unit
 W ith KW  of  Auxiliary heat 
Outdoor 
Ambient 
   °F.
M odel: G SH140241A* / CA*F3636B6A*+TXV / M BR800**1
Condition: 850 CFM  Indoor Air @  70°F DB
Basic Unit w ithout 
Auxiliary Heat
capacity
 btuh
c.o.p.
4.8
9.6
14.4
19.2
65
43.49
4.37
59.875
76.257
92.6394
109.022
60
41.17
4.22
57.556
73.939
90.3212
106.704
55
38.75
4.04
55.134
71.517
87.8992
104.282
50
36.23
3.86
52.609
68.991
85.3734
101.756
45
33.53
3.64
49.910
66.292
82.6746
99.057
40
31.14
3.45
47.522
63.905
80.2872
96.670
35
28.72
3.25
45.100
61.483
77.8652
94.248
30
26.94
2.98
43.325
59.707
76.0895
92.472
25
24.87
2.82
41.249
57.631
74.0137
90.396
20
22.90
2.65
39.281
55.664
72.046
88.428
15
20.82
2.46
37.205
53.588
69.9701
86.353
10
18.68
2.26
35.065
51.447
67.8295
84.212
5
16.56
2.06
32.946
49.328
65.7104
82.093
0
14.44
1.84
30.827
47.209
63.5914
79.974
-5
12.33
1.61
28.708
45.090
61.4723
77.855
-10
10.10
1.35
26.480
42.863
59.2451
75.628
Basic Unit w ithout 
Auxiliary Heat
Model: GSH140361A* / CA*F4860C6A*+TXV / MBR1600**-1
Condition: 1,065 CFM Indoor Air @ 70°F DB
Outdoor 
Ambient 
   °F.
Capacity of Unit
 With KW of Auxiliary heat 
capacity
 btuh
c.o.p.
4.8
9.6
14.4
19.2
65
57.82
4.21
74.204
90.587
106.969
123.352
60
54.74
4.07
71.122
87.505
103.887
120.270
55
51.52
3.90
67.902
84.285
100.67
117.050
50
48.16
3.72
64.544
80.927
97.3092
113.692
45
44.57
3.52
60.956
77.339
93.7212
110.104
40
41.40
3.33
57.782
74.165
90.5472
106.930
35
38.18
3.14
54.562
70.945
87.3272
103.710
30
37.68
3.05
54.058
70.440
86.8225
103.205
25
34.77
2.88
51.155
67.537
83.9198
100.302
20
32.02
2.71
48.403
64.786
81.1682
97.551
15
29.12
2.52
45.501
61.883
78.2654
94.648
10
26.12
2.32
42.507
58.890
75.272
91.654
5
23.16
2.10
39.544
55.926
72.3087
88.691
0
20.20
1.88
36.581
52.963
69.3455
85.728
-5
17.24
1.65
33.617
50.000
66.3823
82.765
-10
14.12
1.38
30.503
46.885
63.2679
79.650
Capacity of Unit
 With KW of Auxiliary heat 
Basic Unit without 
Auxiliary Heat
Model: GSH140481A* / CA*F4860D6A* +TXV / MBR2000**-1
Condition: 1,550 CFM Indoor Air @ 70°F DB
Outdoor 
Ambient 
   °F.
capacity
 btuh
c.o.p.
4.8
9.6
14.4
19.2
65
69.14
4.81
85.517
101.900
118.282
134.665
60
65.45
4.65
81.832
98.215
114.597
130.980
55
61.60
4.46
77.982
94.365
110.747
127.130
50
57.59
4.26
73.967
90.350
106.732
123.115
45
53.30
4.03
69.677
86.060
102.442
118.825
40
49.50
3.82
65.882
82.265
98.647
115.030
35
45.65
3.60
62.032
78.415
94.797
111.180
30
41.02
3.24
57.404
73.787
90.169
106.552
25
37.86
3.06
54.244
70.626
87.009
103.391
20
34.87
2.89
51.248
67.630
84.013
100.395
15
31.70
2.69
48.087
64.470
80.852
97.234
10
28.45
2.47
44.828
61.210
77.593
93.975
5
25.22
2.25
41.601
57.984
74.366
90.749
0
21.99
2.01
38.375
54.757
71.140
87.522
-5
18.77
1.77
35.149
51.531
67.913
84.296
-10
15.38
1.49
31.757
48.140
64.522
80.905
M ODEL GSH140601A* / CA*F4860D6A* +TXV / M BR2000**-1
Condition: 1,850 CFM  Indoor Air @ 70°F DB
Capacity of Unit
 With KW of Auxiliary heat 
Outdoor 
Am bient 
   °F.
Basic Unit without 
Auxiliary Heat
capacity
 btuh
c.o.p.
4.8
9.6
14.4
19.2
65
49.78
4.56
66.160
82.542
98.9244
115.307
60
47.12
4.39
63.506
79.889
96.2712
112.654
55
44.35
4.21
60.734
77.117
93.4992
109.882
50
41.46
4.02
57.844
74.226
90.6084
106.991
45
38.37
3.79
54.755
71.137
87.5196
103.902
40
35.64
3.59
52.022
68.405
84.7872
101.170
35
32.87
3.38
49.250
65.633
82.0152
98.398
30
31.24
3.16
47.627
64.009
80.3919
96.774
25
28.84
2.98
45.220
61.602
77.9846
94.367
20
26.56
2.81
42.938
59.320
75.7027
92.085
15
24.15
2.61
40.531
56.913
73.2954
89.678
10
21.67
2.40
38.048
54.430
70.8129
87.195
5
19.21
2.17
35.591
51.973
68.3554
84.738
0
16.75
1.94
33.133
49.516
65.898
82.280
-5
14.29
1.70
30.676
47.058
63.4405
79.823
-10
11.71
1.43
28.093
44.475
60.8577
77.240
Model: GSH140421A* / CA*F4860D6A*+TXV / MBR2000**-1
Condition: 1,400 CFM Indoor Air @ 70°F DB
Outdoor 
Ambient 
   °F.
Capacity of Unit
 With KW of Auxiliary heat 
Basic Unit without 
Auxiliary Heat
capacity
 btuh
c.o.p.
4.8
9.6
14.4
19.2
65
34.69
4.53
51.076
67.458
83.8404
100.223
60
32.84
4.37
49.226
65.609
81.9912
98.374
55
30.91
4.19
47.294
63.677
80.0592
96.442
50
28.90
4.00
45.280
61.662
78.0444
94.427
45
26.74
3.77
43.127
59.509
75.8916
92.274
40
24.84
3.57
41.222
57.605
73.987
90.370
35
22.91
3.36
39.290
55.673
72.0552
88.438
30
20.93
2.97
37.311
53.694
70.0763
86.459
25
19.32
2.80
35.699
52.081
68.4638
84.846
20
17.79
2.63
34.170
50.553
66.9352
83.318
15
16.18
2.45
32.558
48.940
65.3227
81.705
10
14.51
2.25
30.895
47.277
63.660
80.042
5
12.87
2.04
29.249
45.631
62.0137
78.396
0
11.22
1.82
27.603
43.985
60.3676
76.750
-5
9.57
1.59
25.957
42.339
58.7215
75.104
-10
7.84
1.34
24.227
40.609
56.9914
73.374
Basic Unit without 
Auxiliary Heat
Outdoor 
Ambient 
   °F.
Capacity of Unit
 With KW of Auxiliary heat 
Model: GSH140301A* / CA*F3636B6A*+TXV / MBR1200**-1
Condition: 1,080 CFM Indoor Air @ 70°F DB