HEAT PUMP SPECIFICATIONS
GSH14[018-060]1A*
(1)
 Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
 May use fuses or HACR type Circuit Breakers of the same size as noted.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes.  Use copper wire only.
G
S
H1401
81A*
G
S
H1402
41A*
G
S
H1403
01A*
G
S
H1403
61A*
G
S
H1404
21A*
G
S
H1404
81A*
G
S
H1406
01A*
Cooling Capacity, BTUH
18,000
24,000
28,000
34,600
39,600
46,000
55,000
Compressor
R.L. Amps
9
10.9
12.2
13.4
16
18.3
19.8
L.R. Amps
41.0
54.0
63.0
73.0
88.0
109.0
137.0
Loss of Charge Pressure Switch
Open / Close
7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG 7 PSIG/25 PSIG  7PSIG/25 PSIG 7 PSIG/25 PSIG 7PSIG/25 PSIG
Condenser Fan Motor
Horsepower
1/12
1/6
1/6
1/4
1/4
1/4
1/4
F.L. Amps
0.6
1.1
1.1
1.5
1.5
1.5
1.5
Liquid Line, Inches O.D.
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
Suction Line, Inches O.D.
3/4"
3/4"
3/4"
7/8"
7/8"
7/8"
7/8"
Refrigerant Charge
160
160
165
220
220
280
285
Power Supply
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
208/230-60-1
Minimum Circuit Ampacity
(1)
11.8
14.7
16.3
18.3
21.5
27.8
27.3
Maximum Overcurrent Device
(2)
20
20
20
30
30
40
40
Electrical Conduit Size
Power Supply (Inches)
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
1/2 or 3/4
Approximate Shipping Weight
199
207
207
242
242
266
280