Installation 
4
311628C
Installation
When unpacking pump, check for shipping damage. 
Report any shipping damage to delivering carrier imme-
diately. 
Mounting Pump
1.
Apply herbicide compatible sealant to large thread 
on bung adapter (9) (2 in. x 1-1/2 in. reducer fitting). 
Install bung adapter on tank.
2.
Assemble suction tube sections by applying PVC 
cement (supplied with your pump) to the inside 
diameter of the PVC couplers. Make sure PVC 
cement is applied to the complete inside diameter 
and slide the pipe sections into the coupler with a 
twisting motion. 
3.
Cut the suction tube so that it is 2 in. (55 mm) from 
the bottom of the tank when installed in the tank. 
4.
Insert inlet gasket (7) into union nut (1k). Apply a 
herbicide compatible sealant to the threads on the 
suction tube assembly (5c) and screw the suction 
tube into the pump inlet (1j).
5.
Insert suction tube attached to pump through bung 
adapter (9) into tank. Position pump as desired and 
tighten union nut (1k) on bung adapter (9).
Mounting Hose and Nozzle
1.
Apply herbicide compatible sealant to male threads 
on the street elbow fitting (1e) and screw fitting into 
the 3/4 in. npt outlet port on the top of pump. Do not 
over tighten.
2.
Apply herbicide compatible sealant to threads on 
both ends of the hose assembly. Screw one end of 
hose into the female thread on the fitting (1e) and 
tighten.
3.
Screw nozzle onto the other end of hose and 
tighten.
Electrical Installation 
12 VDC
To install wiring for a negative ground system:
1.
Ensure pump switch is OFF.
2.
To remove electrical cover (2a), remove four bolts 
(2c).
3.
Strip 3 in. (76 mm) of outside insulation from power 
cable (6c) from end opposite of fuse. 
4.
Strip 3/8 in. (10 mm) of insulation from red and black 
wires.
5.
Slide strain relief (6b) over end of power cable (6c) 
on the end just stripped. Male thread of strain relief 
should be toward stripped end.
6.
Insert power cable through conduit thread in electri-
cal cover (2a). Connect wires from power cable to 
wires from the motor using wire nuts (2e): red to red 
and black to black.
CAUTION
Do not use a curb pump automatic shut-off nozzle 
with this pump. Use of a curb pump automatic nozzle 
may cause priming problems, reduced output flow, 
and motor overheating. If an automatic shut-off nozzle 
is required, use Graco part number 260082 (regular) 
or 260083 (unleaded) or Catlow, Inc. part number 
NCLF-1 (regular) or NCNLF-1 (unleaded).
CAUTION
Ensure tank being used is clean and free of welding 
slag. 
Ensure the tank has a vent to allow air into the tank 
as the herbicide is being pumped out. Failure to 
vent tank will cause priming problems.
For tanks deeper than 36 in. (914 mm) you will 
need a standard 1 in. (25 mm) pipe with 1 in. npt 
threads on one end. Suction tubes longer than 60 
in. (1.52 m) require a foot valve (Graco Part No. 
260217) at the bottom of the tube to prevent loss of 
prime.
Power cable can be cut to shorter length if 18 feet 
(5.5 m) is not required. Cut to proper length and 