Graco 260022 Manual De Usuario

Descargar
Página de 16
Troubleshooting 
10
311304H
Troubleshooting
Problem
Cause
Solution
Motor runs but pump will not prime.
Motor rotation wrong. (12 VDC and 
24 VDC units only.)
Check wiring instructions for possible 
problems.
Missing relief valve o-ring seal 
(4c/7a).
Remove gear cover (1b) inspect seal 
(4c/7a), replace if missing or 
damaged.
Sheared drive key (1f/7c).
Remove cover (1b) and inspect key 
(1f/7c/10b), replace if worn or 
sheared.
Dirt under relief poppet (4a) or seal 
(4c/7a).
Remove cover (1b) and inspect, 
clean or replace if damaged.
Strainer seal (3d/7e) leaking.
Inspect and replace if damaged.
Suction height too high to prime.
See Priming Pump, page 9.
Worn or damaged gears.
Remove cover (1b) and inspect 
gears. Replace if worn or damaged.
Fuel level low.
Refill tank.
Cover seal (1e7b/10c) damaged.
Replace if worn or damaged.
Inlet strainer (3b) clogged.
Remove and clean or replace.
Air leak in suction tube.
Inspect all joints in suction tube. 
Make sure all joints in suction tube 
are sealed. and that there are no 
cracks from over-tightening
Air lock in system.
This may occur if filter or meter or 
automatic shut-off nozzle is used. If 
this occurs, fill pump and meter with 
fuel through top of pump.
Motor does not run at proper speed.
Check electric connections. Check 
supply voltage for proper voltage 
level.
Unit pumps but output flow is low.
Clogged inlet strainer (3b).
Clean or replace.
Air leak in suction tube.
Check to make sure all joints in suc-
tion tube are sealed and that there 
are no cracks.
Suction tube too close to tank 
bottom.
Suction tube must have a 2 in. 
(51 mm) minimum clearance.
Tank empty.
Refill tank.
Tank not vented.
Tank must be vented to atmosphere.
Worn or damaged gears.
Remove cover (1b) and inspect 
gears. Replace if worn or damaged.
Damaged motor.
Replace motor.
Clogged suction tube, hose, or 
nozzle.
Inspect and clean.