Graco 260022 Manual De Usuario

Descargar
Página de 16
Installation
311304H
7
3. Cut the suction tube so that it is 2 in. (55 mm) from 
the bottom of the tank when installed in the tank. 
4. Insert gasket (7f) into union nut (1k). If using Graco 
supplied PVC suction tube it is not necessary to 
apply thread tape before assembly, just screw into 
pump inlet (1j). If using metal suction tube (not sup-
plied with pump) then apply thread tape provided 
with pump to NPT threads before assembling to 
pump inlet (1j).
5. Insert suction tube attached to pump through bung 
adapter (9) into tank. Position pump as desired and 
tighten union nut (1k) on bung adapter (9).
Mounting Hose and Nozzle
1. Apply thread tape provided with pump to both ends 
of hose assembly. Screw ¾” NPT end of 90° union 
swivel (15) to one end of hose (see fig. 5).
2. Screw nozzle onto other end of hose and tighten. 
3. Start swivel end of 90° union swivel (15) onto ¾” 
nipple (14) on pump outlet (see F
hose/nozzle assembly to desired position and 
tighten swivel fitting.
It is important that the swivel end of the 90° union 
swivel (15) is assembled to the ¾” outlet nipple (14) 
for proper sealing (see F
. 6). If the pump has diffi-
culty priming, it is easy to remove the swivel and 
pour fluid into the pump outlet cavity when assem-
bled this way. 
F
IG
. 5
F
IG
. 6