Troubleshooting
3A1334E
23 
Troubleshooting
NOTE: Check all other possible problems and solutions 
before disassembling the pump. Before you troubleshoot 
problems using the table below, relieve the pressure 
and disconnect the pump fluid line. If the pump starts 
when the air is turned on again, the fluid line, dispensing 
valve, etc. clogged.
Oil Models
Problem
Cause
Solution
Pump runs but no fluid output
Pump is not fully primed
Crack a fitting at the outlet of the 
pump to allow a slow leak to purge 
any air in the pump. Repeat start up 
procedure, page 11.
Oil leakage 
Check connection and tighten.
The piston valve is not seating prop-
erly or the piston o-ring is damaged
Check and replace parts as needed.
Exhausted fluid supply
Refill and reprime.
The pump inlet filter is blocked
Clear the filter
The suction tube (hose) has an air 
leak
Check the connection and tighten as 
needed.
Pump fails to operate or stops
Damaged pilot valve
Service pilot valve.
Lower air pressure to prevent reoc-
currence.
Damaged main air valve
Replace air valve.
Lower air pressure to prevent reoc-
cur an ce.
Inadequate air supply pressure or 
restricted air lines.
Increase air supply; clear.
Closed or clogged dispensing valve
Open valve if closed. Clear clog if 
necessary.
Clogged fluid lines, hose valves, etc.
Clear clogs.
Damaged air motor
Service air motor.
Erratic or accelerated operation
Exhausted fluid supply
Refill and reprime.
Damaged valve gasket
Replace valve gasket.
Lower air pressure to prevent reoc-
currence.