Installation 
10
332291C
System Configuration and Wiring
If the product is permanently connected:
it must be installed by a qualified electrician or ser-
viceman.
it must be connected to a grounded, permanent wir-
ing system.
If an attachment plug is required in the end use 
application:
it must be rated for the product electrical specifica-
tions.
it must be an approved, 3-wire grounding type 
attachment plug.
it must be plugged into an outlet that is properly 
installed and grounded in accordance with all local 
codes and ordinances.
when repair or replacement of the power cord or 
plug is required, do not connect the grounding wire 
to either flat blade terminal.
Fuses
Fuse Kits are available from Graco. The following Table 
identifies the correct fuse to use for your input voltage 
and the corresponding Graco Kit number.
Recommendations for Using Pump in 
Harsh Environments
Use pump with CPC style power cable.
If using a DIN style power or alarm harness with a 
right angle mating connector, make sure the con-
nector does not exit the unit in the UP direction.
Use a corrosion preventative electrical grease on all 
contacts.
.
Improper installation of the grounding conductor may 
result in a risk of electric shock. This product must be 
installed by a qualified electrician in compliance with 
all state and local codes and regulations.
NOTICE
Fuses (user supplied) are required on all DC mod-
els. To avoid equipment damage:
Never operate G3 Pump DC models without a 
fuse installed.
A fuse of the correct voltage must be installed in 
line with the power entry to the system. 
Input Voltage
Fuse Value
Graco Kit No.
12 VDC
7.5 A
571039
24 VDC
4 A
571040