Troubleshooting
309966J
7
Troubleshooting
Relieve pressure before you check or service any 
system equipment.
Problem
Cause
Solution
Pump fails to operate
Inadequate air supply pressure or 
restricted air lines
Increase air supply and/or clear 
restriction.
Closed or clogged pump valves
Open and/or clean.
Clogged fluid line, hose, valve, or 
other accessory
Relieve pressure.
Clear obstruction.
Damaged air motor
Assess damage, and service air 
motor.
Exhausted fluid supply
Refill and reprime or flush.
Continuous air exhaust
Worn or damaged air motor
gasket or seal
Assess wear or damage, and service 
air motor.
Erratic pump operation
Exhausted fluid supply
Refill and reprime or flush.
Worn pump seals
Replace.
Damaged shovel tube
Replace.
Damaged check seat
Replace pump piston or shovel rod 
(or other damaged part).
Errataic or accelerated pump speed
Exhausted fluid supply
Refill and reprime of flush.
Fluid too heavy for pump priming
Use inductor or follow plate.
Held open or worn piston valve or 
seal
Clear valve; replace seal.
Held open or worn intake valve or 
seal.
Clear valve; replace seal.
Pump operates, but output low on up 
stroke
Worn piston seal
Replace.
Damaged upper check seat
Replace pump piston.
Pump operates, but output low on 
down stroke
Worn fluid intake seal
Replace.
Damaged lower check seat
Replace shovel rod.
Pump operates, but output low on 
both strokes
Inadequate air supply pressure or 
restricted air lines
Increase air supply and/or clear 
restriction.
Closed or clogged pump valves
Open and/or clean.
Exhausted fluid supply
Refill fluid supply, and reprime pump.
Clogged fluid line, hose, valve, or 
other accessory
Relieve pressure.
Clear obstruction.
Worn seals
Replace.
Grease leaking from muffler plates
Worn throat seal
Replace.