Troubleshooting
3A2257C
11
Troubleshooting 
* Oil level in sight well will rise and fall during normal operation. If condition persists refer to Cause/Solution sections.
I
Problem
Cause
Solution
Pump does not flow
Pump stroke is adjusted to zero.
Adjust pump stroke for desired out-
put. See page 8.
Pump outlet is plugged.
Clean/flush pump outlet.
Outlet check valve damaged.
Replace pump.
Pump inlet check ball and/or seat is 
damaged or worn.
Pump has low flow
Pump stroke is adjusted to minimal 
travel.
Adjust pump stroke for desired out-
put. See page 8.
Pump inlet check ball and/or seat is 
damaged or worn.
Replace pump.
Outlet check valve damaged.
Pump has low discharge pressure
Piston and bore are worn.
Replace pump.
Pump inlet check valve and/or seat 
are damaged or worn.
Fluid flow from pump outlet when 
pump is not running
Inlet pressure exceeds outlet check 
pressure.
Reduce inlet pressure to below out-
let check pressure.
Pump outlet check ball and/or seat 
is damaged or worn.
Replace pump.
Sight well fills with oil*
Possible debris in inlet check
Perform Maintenance, page 12.
Pump inlet check ball and/or seat is 
damaged or worn
Replace pump.
Piston and bore are worn
Sight well runs dry*
Restriction in Drip or Suction tube
Perform Maintenance, page 12.
Air leak in sight well
Replace pump.
Sight well remains constant and no 
lubricant drips from tube
Pump air bound
Follow Setup section appropriate for 
your pump model, pages 5-8.
Pump regulation set too low
Increase pump regulation.
Camshaft speed too slow
Increase camshaft speed (see Table 
1, page 10.
Cloudy or broken sight glass (Suc-
tion or Gravity Fed Pumps only)
NA
Replace sight glass using GBL7500 
Sight Glass Replacement Kit 
24T306. See Maintenance, page 
12.