Warnings 
4
3A2257C
Pressure Relief Procedure
1.
Stop lube pump.
2.
If installed, close oil supply valve located upstream 
from pump.
3.
If installed, open drain valve located downstream 
from the pump.
4.
Slowly crack open fluid line fittings to relieve pres-
sure.
Installing the Pump
Grounding
Ensure the reservoir is properly grounded as the pump 
is grounded through the mounting screws.
Mounting Pump
NOTE: 
Ensure box and lube system are sized appropriately 
for the selected pressure. 
Ensure an appropriate pressure relief device, suit-
able for your application, is installed in the system.
Inspect your box lubricator and replace any dam-
naged or worn components.
1.
Ensure the pump mounting surface on the reservoir 
cover is clean. Clean as needed.
2.
Align gasket (a) with opening on the top of the reser-
voir cover making sure holes (b) on either end of the 
gasket match mounting holes (c) in reservoir cover 
(F
IG
. 1).
NOTE: Alarm Pumps Only - For optimum perfor-
mance, mount alarm pump in location furthest from 
drive motor.
For Gravity and Pressure Fed pumps, skip Step 
3 an
d continue installation with Step 4.
For Alarm pumps skip Step 3a and continue 
installation with Step 3b
.
Pressure Fed pumps follow Step 3a and 3b.
3.
For Suction Fed Pumps install pump inlet strainer:
a.
Check length of suction tube. If it is too long to 
fit in the reservoir, use a pliers to break off the 
lower section of the tube (a) (F
. 2).
Follow the Pressure Relief Procedure whenever 
you see this symbol.
I
This equipment stays pressurized until pressure is 
manually relieved. To help prevent serious injury from 
pressurized fluid, such as skin injection, splashing 
fluid and moving parts, follow the Pressure Relief 
Procedure when you stop pumping and before 
cleaning, checking or servicing the equipment.
The equipment must be grounded to reduce the risk 
of static sparking. Static sparking can cause fumes to 
ignite or explode. Grounding provides an escape wire 
for the electric current.