Graco 239731 Manual De Usuario

Descargar
Página de 18
Technical Data
308777L
15
Technical Data
.
Sound Pressure Level 
(measured at 1 meter from unit)
Sound Power Level 
(tested in accordance with ISO 9614-2)
75:1 Fire-Ball
®
 425 Pumps
US
Metric
Fluid pressure ratio
75:1
Air pressure operating range
40 to 100 psi
0.3 to 0.7 MPa, 3 to 7 bar
Maximum working pressure
7500 psi
51.7 MPa, 517 bar
Maximum delivery
0.33 gpm
1.3 lpm
Cycles per gallon (liter)
165 
42
Maximum recommended pump speed
60 cycles/minute
Air motor effective diameter
4.25 inches
108 mm
Stroke
4 inches 
102 mm
Air consumption
approximately 26 cfm at 1 
gpm, at 70 psi
approximately 0.72 m
3
/min at 
1 gpm, at 0.5 MPa, 5 bar
Wetted Parts
steel, brass, aluminum, leather
Weight
Model 239729
34 lb
15 kg
Model 239730
37 lb
17 kg
Model 239731
30 lb
14 kg
Input Air Pressures at 15 cycles per minute
40 psi (0.28 MPa, 2.8 bar)
70 psi (0.48 MPa, 4.8 bar)
100 psi (0.7 MPa, 7 bar)
73.6 dB(A)
78.34 dB(A)
80.85 dB(A)
Input Air Pressures at 15 cycles per minute
40 psi (0.28 MPa, 2.8 bar)
70 psi (0.48 MPa, 4.8 bar)
100 psi (0.7 MPa, 7 bar)
87.4 dB(A)
92.09 dB(A)
94.62 dB(A)