Instructions
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever you 
see this symbol.
To relieve pressure in the system, use two wrenches working 
in opposite directions on pump outlet fitting to slowly loosen 
fitting only
 until fitting is loose and no more lubricant or air is 
leaking from fitting as shown in F
IG
. 1.
NOTE: When loosening pump element fitting do NOT loosen 
pump element. Loosening pump element will change the out-
put volume.
Technical Data
Disassembly
The following instructions are for removing the pump element 
currently installed in the G3 Pump. Reference numbers used 
in these instructions correspond to parts included in the kit and 
are provided on page 1. Parts identified with an alpha charac-
ter are user provided or already installed components.
1.
Disconnect power source.
2.
Relieve pressure following Pressure Relief Procedure 
provided.
3.
Disconnect anything installed to pump element such as 
pressure relief valves, output union or other fittings.
4.
Use a wrench to loosen pump element (1) and completely 
remove pump element (F
NOTE: Make sure spring (a) retainer (b) and piston (not 
shown) are removed with pump element.
5.
Remove zerk fitting (2) and plugs (3) as shown in F
Installation
1.
Examine new pump element (1). Make sure spring (a), 
retainer (b) and piston are installed (F
2.
Slide pump element into housing. Be careful not to cross 
thread the pump element during installation.
3.
Hand tighten pump and then torque to 50 in.-lbs (5.6 N•m) 
(F
IG
. 1).
4.
Apply thread sealant to stainless steel zerk fitting (2) and 
install zerk fitting as shown in F
. 2. Torque to 50 in.-lbs 
(5.6 N•m).
5.
Apply thread sealant to stainless steel plugs (3) and install 
plugs as shown in Fig. 2. Torque to 50 in.-lbs (5.6 N•m).
This equipment stays pressurized until pressure is 
manually relieved. To help prevent serious injury from 
pressurized fluid, such as skin injection, splashing fluid and 
moving parts, follow the Pressure Relief Procedure when 
you stop dispensing and before cleaning, checking, or 
servicing the equipment.
F
IG
. 1
US
Metric
Maximum Working 
Pressure
5100 psi
35.1 MPa, 351.6 bar
Wetted Parts
nylon 6/6 (PA), zinc plated steel, alloy 
steel, stainless steel, nitrile rubber 
(buna-N), PTFE
F
IG
. 2
1
a
b
3
2
3