Troubleshooting
3A2257C
11
Troubleshooting
* Oil level in sight well will rise and fall during normal operation. If condition persists refer to Cause/Solution sections.
I
Problem
Cause
Solution
Pump does not flow
Pump stroke is adjusted to zero.
Adjust pump stroke for desired out-
put. See page 8.
put. See page 8.
Pump outlet is plugged.
Clean/flush pump outlet.
Outlet check valve damaged.
Replace pump.
Pump inlet check ball and/or seat is
damaged or worn.
damaged or worn.
Pump has low flow
Pump stroke is adjusted to minimal
travel.
travel.
Adjust pump stroke for desired out-
put. See page 8.
put. See page 8.
Pump inlet check ball and/or seat is
damaged or worn.
damaged or worn.
Replace pump.
Outlet check valve damaged.
Pump has low discharge pressure
Piston and bore are worn.
Replace pump.
Pump inlet check valve and/or seat
are damaged or worn.
are damaged or worn.
Fluid flow from pump outlet when
pump is not running
pump is not running
Inlet pressure exceeds outlet check
pressure.
pressure.
Reduce inlet pressure to below out-
let check pressure.
let check pressure.
Pump outlet check ball and/or seat
is damaged or worn.
is damaged or worn.
Replace pump.
Sight well fills with oil*
Possible debris in inlet check
Perform Maintenance, page 12.
Pump inlet check ball and/or seat is
damaged or worn
damaged or worn
Replace pump.
Piston and bore are worn
Sight well runs dry*
Restriction in Drip or Suction tube
Perform Maintenance, page 12.
Air leak in sight well
Replace pump.
Sight well remains constant and no
lubricant drips from tube
lubricant drips from tube
Pump air bound
Pump regulation set too low
Increase pump regulation.
Camshaft speed too slow
Increase camshaft speed (see Table
1, page 10.
1, page 10.
Cloudy or broken sight glass (Suc-
tion or Gravity Fed Pumps only)
tion or Gravity Fed Pumps only)
NA