Repair 
12
3A1450D
Repair
Disassembly
1.
Relieve the pressure, see 
2.
Disconnect the hoses from the lower and plug the 
ends to prevent fluid contamination.
3.
See F
IG
. 4. Remove the 2-piece shield (109) by 
inserting a screwdriver straight into the slot, and 
using it as a lever to release the tab. Repeat for all 
tabs. 
Do not
 use the screwdriver to pry the shields 
apart.
4.
Loosen the coupling nut (110) and remove the col-
lars (111). Remove the coupling nut from the piston 
rod (R). Unscrew the locknuts (105) from the tie 
rods (104). Separate the motor (101) and lower 
(102). See F
IG
. 5.
5.
To repair the air motor or lower, see the separate 
manuals listed under 
 on page 2.
Reassembly
NOTE:
 If the coupling adapter (108) and tie rods (104) 
have been disassembled from the motor, see 
 
on page 13.
1.
See F
IG
. 5. Assemble the coupling nut (110) to the 
piston rod (R).
2.
Orient the lower (102) to the motor (101). Position 
the lower on the tie rods (104). Lubricate the 
threads of the tie rods. Screw the tie rod locknuts 
(105) onto the tie rods. Tighten the locknuts and 
torque to 50-55 ft-lb (68-75 N•m).
3.
Insert the collars (111) into the coupling nut (110). 
Tighten the coupling nut onto the coupling adapter 
(108) and torque to 75-80 ft-lb (102-109 N•m).
4.
See F
IG
. 4. Install the shields (109) by engaging the 
bottom lips with the groove in the wet-cup cap. Snap 
the two shields together.
5.
Flush and test the pump before reinstalling it in the 
system. Connect hoses and flush the pump. While it 
is pressurized, check for smooth operation and 
leaks. Adjust or repair as necessary before reinstall-
ing in the system. Reconnect the pump ground wire 
before operating.
F
IG
. 4. Disassembly and Reassembly of the Shields
ti15759a
Shield Disassembly
ti15770a
ti15757a
ti15758a
Shield Reassembly