Operation 
8
3A1450D
Operation
Pressure Relief Procedure
1.
Close the bleed-type master air valve (M).
2.
Open the dispensing valve, if used.
3.
Open all fluid drain valves (N) in the system, having 
a waste container ready to catch drainage. Leave 
drain valve(s) open until you are ready to pump 
again.
Prime the Pump
1.
Fill the TSL reservoir to the Maximum fill line with 
Throat Seal Liquid (TSL). See F
. 3 on page 10.
NOTE: 
During operation the TSL level in the reservoir 
will fluctuate slightly at pump changeover.
2.
Close pump air regulator (L) by turning knob coun-
terclockwise reducing pressure to zero. Close 
bleed-type air valve (M). Also verify that all drain 
valves (N) are closed.
3.
Connect air line (J) to bleed type air valve (M).
4.
Check that all fittings throughout system are tight-
ened securely.
5.
Connect the fluid supply line (C) from the mix tank 
shutoff valve (D) to the pump. 
6.
Connect the fluid line (E) to the pump outlet.
7.
Open bleed-type air valve (M). Slowly turn pump air 
regulator (L) clockwise, increasing pressure until 
pump starts.
8.
Cycle pump slowly until all air is pushed out and 
pump and hoses are fully primed.
9.
Verify that pump actuations are priming the pump 
wet-cup. If not, confirm that the TSL pump piston is 
being depressed at bottom changeover, and that 
reservoir check valves are not stuck closed.
10. Close the fluid shutoff valve (D) downstream of the 
pump. The pump should stall against pressure.
NOTE:
 In a circulation system, the pump operates con-
tinuously until the power supply is shut off. In a 
direct-supply system, the pump starts when the dis-
pense valve is opened, and stops when the dispense 
valve is closed.
Stop the Pump at the Bottom of 
Its Stroke
Relieve the pressure when you stop the pump for any 
reason. Stop the pump on the downstroke, before the air 
motor changes over.
Shutdown
Follow 
, page 8.
Always flush the pump before the fluid dries on the dis-
placement rod. Se
 on page 9.
NOTICE
Failure to stop the pump at the bottom of its stroke 
allows fluid to dry on the piston rod, which can dam-
age the throat packings and the TSL pump piston seal 