Indoor Model # 
 
Outdoor Model # 
UCHW-H09AF2 
 
UCHW-H09CF2 
UCHW-H12AF2 
 
UCHW-H12CF2 
UCHW-H18AF2 
 
UCHW-H18CF2 
UCHW-H24AF2 
 
UCHW-H24CF2 
Capacity (BTU) 
 
 
 
 
Cooling 
9,000 
12,000 
17,000 
24,000 
Heating 
11,000 
14,500 
18,700 
25,000 
SEER 
13.0 
13.0 
13.0 
13.0 
HSPF 
 
 
 
 
Op Range Cool 
50 - 109
50 - 109 
50 - 109 
50 - 109 
Op Range Heat 
14 - 109 
14 - 109 
14 - 109 
14 - 109 
Voltage 
115-60-1 
115-60-1 
230/208-60-1 
230/208-60-1 
Input Current (A) 
7.2 
9.6 
6.5 
8.5 
Air Circulation CFM  
295 400  648 735 
Noise level dB(A)  
35/42 
36/45 
43/49 
43/49 
Outdoor Noise Level dB(A) 
54 
60 
59 
59 
Fan Speeds 
3 + Auto 
3 + Auto 
3 + Auto 
3 + Auto 
 
 
 
 
 
Connection Method 
Flare 
Flare 
Flare 
Flare 
Max Pipe Length (Ft.) 
50 
50 
100 
100 
Max Elevation (Ft.) 
25 
25 
50 
50 
Pipe Size (In.) 
1/4—1/2 1/4—1/2  3/8—5/8 3/8—5/8 
Service Port Connection (In.) 
5/16 
5/16 
5/16 
5/16 
Indoor Dimensions 
W x H x D 
 
34-
1/4 
x 13-
3/4 
x 9-
5/8
 
 
39-
3/4
 
x 13-
3/4 
x 10-
1/4
 
 
46-
1/4 
x 15-
1/2 
x 12
-
5/8 
 
52-
1/2 
x 16-
1/8 
x 12-
1/8 
   Net Weight (lbs.) 
22 
35 
40 
44 
Outdoor Dimensions 
23-
1/2 
x 36-
1/4 
x 13-
1/4
  27-
1/8 
x 39-
1/8 
x 16-
3/8 
40-
1/2 
x 37-
3/4 
x 17-
3/8 
40-
1/2 
x 37-
3/4 
x 17-
3/8 
   Net Weight (lbs.) 
73 
110 
143 
143 
Refrigerant 
R-410A 
R-410A 
R-410A 
R-410A 
Some specifications above are from preliminary data and may change with final product. Please contact Amcor for updates and review installation materials 
prior to installing. 
Amcor Inc. 685A Gotham Parkway, Carlstadt, NJ 07072  
www.amcorgroupusa.com 
         (201) 
460-8100