PERFORMANCE DATA (cont)
COMBINATION RATINGS (cont)
UNIT 566E180
LEGEND
566E180/524A-C150 WITH HIGH-CAPACITY 4-ROW COIL
Temp (F)
Air Entering
Condenser
(Edb)
Evaporator Air — Cfm
3750
5000
6250
Evaporator Air — Ewb (F)
57
62
67
72
57
62
67
72
57
62
67
72
80
TC
163.0
175.0
190.0
206.0
179.0
186.0
201.0
217.0
191.0
194.0
208.0
224.0
SHC
161.0
142.0
121.0
99.8
179.0
164.0
138.0
110.0
191.0
184.0
153.0
119.0
kW
12.60
12.80
13.20
13.60
12.90
13.10
13.40
13.80
13.20
13.30
13.60
14.00
85
TC
160.0
172.0
187.0
203.0
176.0
183.0
198.0
214.0
188.0
190.0
204.0
220.0
SHC
159.0
141.0
120.0
98.5
176.0
163.0
136.0
109.0
188.0
182.0
151.0
118.0
kW
13.10
13.40
13.80
14.20
13.50
13.70
14.00
14.40
13.80
13.80
14.20
14.60
95
TC
155.0
166.0
180.0
196.0
170.0
176.0
190.0
206.0
181.0
183.0
196.0
212.0
SHC
155.0
138.0
117.0
95.6
170.0
159.0
133.0
106.0
181.0
178.0
148.0
115.0
kW
14.30
14.60
15.00
15.40
14.70
14.80
15.20
15.70
15.00
15.00
15.40
15.80
100
TC
152.0
163.0
177.0
192.0
167.0
172.0
186.0
201.0
178.0
180.0
192.0
208.0
SHC
152.0
136.0
115.0
94.0
167.0
158.0
131.0
104.0
178.0
176.0
146.0
113.0
kW
14.90
15.20
15.60
16.00
15.30
15.50
15.80
16.30
15.60
15.60
16.00
16.50
105
TC
150.0
159.0
173.0
188.0
164.0
168.0
182.0
197.0
175.0
176.0
188.0
203.0
SHC
150.0
134.0
114.0
92.4
164.0
156.0
130.0
102.0
175.0
173.0
145.0
112.0
kW
15.60
15.80
16.20
16.60
16.00
16.10
16.50
16.90
16.30
16.30
16.60
17.10
115
TC
144.0
152.0
165.0
179.0
158.0
161.0
173.0
188.0
168.0
168.0
178.0
193.0
SHC
144.0
131.0
110.0
89.1
158.0
152.0
126.0
99.0
168.0
167.0
141.0
108.0
kW
16.90
17.10
17.50
18.00
17.30
17.40
17.80
18.20
17.60
17.60
17.90
18.40
566E180/524A-B150 WITH STANDARD 3-ROW COIL
Temp (F)
Air Entering
Condenser
(Edb)
Evaporator Air — Cfm
3750
5000
6250
Evaporator Air — Ewb (F)
57
62
67
72
57
62
67
72
57
62
67
72
80
TC
154.0
166.0
181.0
196.0
168.0
176.0
191.0
206.0
179.0
183.0
197.0
213.0
SHC
152.0
134.0
115.0
94.7
168.0
154.0
129.0
104.0
179.0
171.0
143.0
112.0
kW
12.40
12.60
13.00
13.30
12.70
12.90
13.20
13.60
12.90
13.00
13.40
13.70
85
TC
152.0
163.0
178.0
193.0
166.0
173.0
188.0
203.0
176.0
180.0
194.0
210.0
SHC
150.0
133.0
113.0
93.4
166.0
153.0
128.0
102.0
176.0
169.0
141.0
111.0
kW
12.90
13.20
13.50
13.90
13.20
13.40
13.80
14.20
13.50
13.60
13.90
14.30
95
TC
147.0
157.0
171.0
186.0
160.0
167.0
180.0
196.0
171.0
173.0
187.0
202.0
SHC
146.0
130.0
111.0
90.6
160.0
149.0
125.0
99.7
171.0
166.0
138.0
108.0
kW
14.10
14.40
14.70
15.10
14.40
14.60
15.00
15.40
14.70
14.80
15.10
15.50
100
TC
144.0
154.0
168.0
182.0
158.0
163.0
177.0
191.0
167.0
170.0
182.0
197.0
SHC
144.0
128.0
109.0
89.1
158.0
148.0
123.0
98.1
167.0
163.0
137.0
106.0
kW
14.80
15.00
15.30
15.70
15.10
15.20
15.60
16.00
15.30
15.40
15.70
16.20
105
TC
141.0
151.0
164.0
179.0
155.0
160.0
173.0
187.0
164.0
166.0
178.0
193.0
SHC
141.0
127.0
107.0
87.6
155.0
146.0
122.0
96.5
164.0
161.0
135.0
105.0
kW
15.40
15.60
16.00
16.40
15.70
15.80
16.20
16.60
16.00
16.00
16.40
16.80
115
TC
136.0
144.0
157.0
170.0
149.0
152.0
165.0
178.0
158.0
159.0
170.0
183.0
SHC
136.0
124.0
104.0
84.4
149.0
142.0
118.0
93.3
158.0
156.0
132.0
101.0
kW
16.80
16.90
17.30
17.70
17.10
17.20
17.50
17.90
17.30
17.30
17.70
18.10
Edb — Entering Dry Bulb
Ewb — Entering Wet Bulb
kW
— Compressor Motor Power Input
SHC — Sensible Heat Capacity (1000 Btuh) Gross
TC
— Total Capacity (1000 Btuh) Gross
5
0TF
Q00
4
-012
56
6D
/E1
50-
24